Comparative Analysis of Pulmonary Function in Rice Mill Workers Versus Unexposed Controls: A Pilot Cross-Sectional Study

Introduction Rice milling is a major agro-based industry in India and employs a large number of workers who are chronically exposed to organic and inorganic dust generated during milling operations. Inhalation of rice husk dust, silica residues, fungal spores, and other airborne contaminants may contribute to airway inflammation, fibrosis, and ventilatory impairment. However, standardized spirometric data from Indian rice mill workers remain limited. This study aimed to compare pulmonary function parameters between rice mill workers and unexposed controls. Materials and methods A cross-sectional study was conducted at the Department of Physiology, Karpaga Vinayaga Institute of Medical Sciences, Madhuranthagam. A total of 100 male participants aged 30-60 years were included; of these, 50 were exposed, and 50 were unexposed. Exclusion criteria included smoking, pre-existing respiratory or cardiac disease, inability to perform spirometry adequately, prior exposure to other occupational dust, and recent or active acute respiratory infection. Spirometry was performed using a Medicaid Smart Soft USB software spirometer (Medicaid Systems, Jalandhar, Punjab, India), measuring forced vital capacity (FVC), forced expiratory volume in one second (FEV₁), FEV₁/FVC ratio, and peak expiratory flow rate (PEFR) for both groups. Data were analyzed using SPSS Version 31 (IBM Corp., Armonk, NY, US). Results The PFT of the Rice mill workers showed a significant decrease in FVC (1.96 ± 0.22 L), FEV₁ (1.69 ± 0.21 L), and PEFR (4.47 ± 1.89 L/s) compared to controls (p < 0.05). However, FEV₁/FVC ratio is more than 70%, suggesting a restrictive pattern of lung involvement, with a restrictive spirometric pattern.

Authors

Publication Details

Journal
Cureus
Published
2026-03-26
DOI
https://doi.org/10.7759/cureus.105901
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Analysis of Pulmonary Function in Rice Mill Workers Versus Unexposed Controls: A Pilot Cross-Sectional Study

Nishanth Murugan, Sumitra Sudharkodhy, Prasath Sekar, B Jaya
Cureus
Indoor Air Quality and Microbial Exposure
article

Comparative Analysis of Pulmonary Function in Rice Mill Workers Versus Unexposed Controls: A Pilot Cross-Sectional Study

Nishanth Murugan, Sumitra Sudharkodhy, Prasath Sekar, B Jaya
article en

Abstract

Introduction Rice milling is a major agro-based industry in India and employs a large number of workers who are chronically exposed to organic and inorganic dust generated during milling operations. Inhalation of rice husk dust, silica residues, fungal spores, and other airborne contaminants may contribute to airway inflammation, fibrosis, and ventilatory impairment. However, standardized spirometric data from Indian rice mill workers remain limited. This study aimed to compare pulmonary function parameters between rice mill workers and unexposed controls. Materials and methods A cross-sectional study was conducted at the Department of Physiology, Karpaga Vinayaga Institute of Medical Sciences, Madhuranthagam. A total of 100 male participants aged 30-60 years were included; of these, 50 were exposed, and 50 were unexposed. Exclusion criteria included smoking, pre-existing respiratory or cardiac disease, inability to perform spirometry adequately, prior exposure to other occupational dust, and recent or active acute respiratory infection. Spirometry was performed using a Medicaid Smart Soft USB software spirometer (Medicaid Systems, Jalandhar, Punjab, India), measuring forced vital capacity (FVC), forced expiratory volume in one second (FEV₁), FEV₁/FVC ratio, and peak expiratory flow rate (PEFR) for both groups. Data were analyzed using SPSS Version 31 (IBM Corp., Armonk, NY, US). Results The PFT of the Rice mill workers showed a significant decrease in FVC (1.96 ± 0.22 L), FEV₁ (1.69 ± 0.21 L), and PEFR (4.47 ± 1.89 L/s) compared to controls (p < 0.05). However, FEV₁/FVC ratio is more than 70%, suggesting a restrictive pattern of lung involvement, with a restrictive spirometric pattern.

Cureus
Openalex Percentile: Top 9%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.