Experimental and analytical evaluation of seismic behavior of ICEB masonry walls under in-plane cyclic loading
The study investigates the seismic behavior of full-scale interlocking compressed earth brick (ICEB) masonry walls under in-plane lateral cyclic loading. Five wall specimens constructed using ICEBs with distinct reinforcement ratios and subjected to investigation under quasi-static reversed cyclic loading, simulating seismic demands on low-rise masonry structures. Key performance parameters, including lateral load capacity, stiffness degradation, ductility, energy dissipation, viscous damping, and failure mechanisms, are measured and analyzed. The dry-stacked interlocking geometry facilitated stable hysteretic behavior, with energy dissipation occurring through inter-brick sliding and friction. Among the tested configurations, the wall with a vertical reinforcement ratio (0.17%) and corner stirrup confinement demonstrated improved post-peak stability and more distributed damage. A wall without stirrups but with a higher vertical reinforcement ratio (0.23%) achieved a comparable peak lateral resistance. However, this substitution effect was limited to lower drift demands below approximately 2.0%. At larger drift levels, stirrup confinement proved more effective in preserving residual strength and mitigating rapid stiffness degradation. Experimental results were further evaluated using TMS 402/602–16 and CSA S304–14 provisions, as well as a unified analytical shear model. The comparison indicates that conventional masonry codes tend to overestimate the lateral capacity of dry-stack ICEB walls due to inherent cohesion assumptions. In contrast, the unified model, when applied within the context of friction-governed dry-stack mechanics, provides a more consistent and conservative prediction of the seismic shear capacity of ICEB masonry walls. • Reinforcement boosts ICEB wall strength and ductility under in-plane cyclic loads. • Dry-stack ICEBs show stable hysteresis and energy dissipation for in-plane shear. • Codes overestimate ICEB in-plane shear capacity, whereas unified model fits better. • ICEB offers sustainable, seismic-safe housing alternative.
Authors
- Azam Khan (ORCID: https://orcid.org/0000-0001-9214-9088)
- Tatheer Zahra (ORCID: https://orcid.org/0000-0003-1930-5704)
- Junaid Shah Khan (ORCID: https://orcid.org/0000-0003-0315-1413)
- Azam Khan (ORCID: https://orcid.org/0000-0002-9071-7106)
Institutions
- Queensland University of Technology (AU)
- National University of Sciences and Technology (PK)
Publication Details
- Journal
- Construction and Building Materials
- Published
- 2026-03-26
- DOI
- https://doi.org/10.1016/j.conbuildmat.2026.146038
- Primary Topic
- Masonry and Concrete Structural Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00