Experimental and analytical evaluation of seismic behavior of ICEB masonry walls under in-plane cyclic loading

The study investigates the seismic behavior of full-scale interlocking compressed earth brick (ICEB) masonry walls under in-plane lateral cyclic loading. Five wall specimens constructed using ICEBs with distinct reinforcement ratios and subjected to investigation under quasi-static reversed cyclic loading, simulating seismic demands on low-rise masonry structures. Key performance parameters, including lateral load capacity, stiffness degradation, ductility, energy dissipation, viscous damping, and failure mechanisms, are measured and analyzed. The dry-stacked interlocking geometry facilitated stable hysteretic behavior, with energy dissipation occurring through inter-brick sliding and friction. Among the tested configurations, the wall with a vertical reinforcement ratio (0.17%) and corner stirrup confinement demonstrated improved post-peak stability and more distributed damage. A wall without stirrups but with a higher vertical reinforcement ratio (0.23%) achieved a comparable peak lateral resistance. However, this substitution effect was limited to lower drift demands below approximately 2.0%. At larger drift levels, stirrup confinement proved more effective in preserving residual strength and mitigating rapid stiffness degradation. Experimental results were further evaluated using TMS 402/602–16 and CSA S304–14 provisions, as well as a unified analytical shear model. The comparison indicates that conventional masonry codes tend to overestimate the lateral capacity of dry-stack ICEB walls due to inherent cohesion assumptions. In contrast, the unified model, when applied within the context of friction-governed dry-stack mechanics, provides a more consistent and conservative prediction of the seismic shear capacity of ICEB masonry walls. • Reinforcement boosts ICEB wall strength and ductility under in-plane cyclic loads. • Dry-stack ICEBs show stable hysteresis and energy dissipation for in-plane shear. • Codes overestimate ICEB in-plane shear capacity, whereas unified model fits better. • ICEB offers sustainable, seismic-safe housing alternative.

Authors

Institutions

Publication Details

Journal
Construction and Building Materials
Published
2026-03-26
DOI
https://doi.org/10.1016/j.conbuildmat.2026.146038
Primary Topic
Masonry and Concrete Structural Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experimental and analytical evaluation of seismic behavior of ICEB masonry walls under in-plane cyclic loading

Azam Khan, Tatheer Zahra, Junaid Shah Khan, Azam Khan
Construction and Building Materials
Masonry and Concrete Structural Analysis
article

Experimental and analytical evaluation of seismic behavior of ICEB masonry walls under in-plane cyclic loading

Azam Khan, Tatheer Zahra, Junaid Shah Khan, Azam Khan
article en

Abstract

The study investigates the seismic behavior of full-scale interlocking compressed earth brick (ICEB) masonry walls under in-plane lateral cyclic loading. Five wall specimens constructed using ICEBs with distinct reinforcement ratios and subjected to investigation under quasi-static reversed cyclic loading, simulating seismic demands on low-rise masonry structures. Key performance parameters, including lateral load capacity, stiffness degradation, ductility, energy dissipation, viscous damping, and failure mechanisms, are measured and analyzed. The dry-stacked interlocking geometry facilitated stable hysteretic behavior, with energy dissipation occurring through inter-brick sliding and friction. Among the tested configurations, the wall with a vertical reinforcement ratio (0.17%) and corner stirrup confinement demonstrated improved post-peak stability and more distributed damage. A wall without stirrups but with a higher vertical reinforcement ratio (0.23%) achieved a comparable peak lateral resistance. However, this substitution effect was limited to lower drift demands below approximately 2.0%. At larger drift levels, stirrup confinement proved more effective in preserving residual strength and mitigating rapid stiffness degradation. Experimental results were further evaluated using TMS 402/602–16 and CSA S304–14 provisions, as well as a unified analytical shear model. The comparison indicates that conventional masonry codes tend to overestimate the lateral capacity of dry-stack ICEB walls due to inherent cohesion assumptions. In contrast, the unified model, when applied within the context of friction-governed dry-stack mechanics, provides a more consistent and conservative prediction of the seismic shear capacity of ICEB masonry walls. • Reinforcement boosts ICEB wall strength and ductility under in-plane cyclic loads. • Dry-stack ICEBs show stable hysteresis and energy dissipation for in-plane shear. • Codes overestimate ICEB in-plane shear capacity, whereas unified model fits better. • ICEB offers sustainable, seismic-safe housing alternative.

Construction and Building MaterialsVol. 521
Queensland University of Technology (AU), National University of Sciences and Technology (PK)
Openalex Percentile: Top 8%
Masonry and Concrete Structural Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.