Feasibility of Free-breathing Deep Learning–reconstructed Single-Shot Cine MRI in Participants with Arrhythmia: Comparison with Conventional Segmented Cine MRI

Purpose To evaluate the feasibility of retrospective electrocardiographically (ECG) gated single-shot cine using deep learning-enhanced compressed sensing (AI-CS) versus conventional balanced steady-state free precession (bSSFP) cine, focusing on left ventricular (LV) structure and function. Materials and Methods Between September 1, 2023, and September 28, 2024, participants (including those with suspected arrhythmias) were prospectively recruited to undergo short-axis cine imaging with both bSSFP and AI-CS single-shot sequences on a 1.5-T scanner. LV volumetric parameters (LV end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, and mass) and strain parameters (peak strain in the radial, longitudinal, and circumferential directions and the time to peak strain SD) were measured and compared using Wilcoxon signed rank tests. Results Among 25 healthy volunteers (mean age, 37.88 years ± 16.76 [SD]; 18 female) and 45 participants with suspected arrhythmia (mean age, 53.21 years ± 15.45; 20 female), the AI-CS single-shot cine had better image quality compared with bSSFP cine, particularly in participants with arrhythmia (European Cardiovascular Magnetic Resonance Registry score: 0.32 ± 0.68 for bSSFP cine vs 0.05 ± 0.22 for AI-CS single-shot cine; <i>P</i> < .001), with fewer mistrigger events and cardiac motion artifacts. AI-CS showed good to excellent agreement with bSSFP for biventricular volume and LV mass measurements and provided comparable ejection fraction values to those at echocardiography in cases in which bSSFP failed (37.50% ± 5.28 vs 31.70% ± 6.43; <i>z</i> = -1.864; <i>P</i> = .06). Scan time was significantly reduced with AI-CS (10 seconds ± 2 vs 132 seconds ± 8; <i>P</i> < .001). Conclusion AI-CS single-shot cine demonstrated greater image quality and clinical feasibility compared with bFFSP cine in healthy participants and participants with suspected arrhythmias. <b>Keywords:</b> Artificial Intelligence-assisted Compressed SENSE, Arrhythmias, Left Ventricular Structure, Left Ventricular Function, Cardiac MRI, Balanced Steady-State Free Precession Cine Sequences <i>Supplemental material is available for this article.</i> © RSNA, 2026.

Authors

Institutions

Publication Details

Journal
Radiology Cardiothoracic Imaging
Published
2026-03-26
DOI
https://doi.org/10.1148/ryct.250298
Primary Topic
Cardiac Imaging and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of Free-breathing Deep Learning–reconstructed Single-Shot Cine MRI in Participants with Arrhythmia: Comparison with Conventional Segmented Cine MRI

Caizhong Chen, Fan Du, Xiuzheng Yue, Nan Zhang et al.
Radiology Cardiothoracic Imaging
Cardiac Imaging and Diagnostics
article

Feasibility of Free-breathing Deep Learning–reconstructed Single-Shot Cine MRI in Participants with Arrhythmia: Comparison with Conventional Segmented Cine MRI

Caizhong Chen, Fan Du, Xiuzheng Yue, Nan Zhang, Hang Jin, Mengsu Zeng
article en

Abstract

Purpose To evaluate the feasibility of retrospective electrocardiographically (ECG) gated single-shot cine using deep learning-enhanced compressed sensing (AI-CS) versus conventional balanced steady-state free precession (bSSFP) cine, focusing on left ventricular (LV) structure and function. Materials and Methods Between September 1, 2023, and September 28, 2024, participants (including those with suspected arrhythmias) were prospectively recruited to undergo short-axis cine imaging with both bSSFP and AI-CS single-shot sequences on a 1.5-T scanner. LV volumetric parameters (LV end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, and mass) and strain parameters (peak strain in the radial, longitudinal, and circumferential directions and the time to peak strain SD) were measured and compared using Wilcoxon signed rank tests. Results Among 25 healthy volunteers (mean age, 37.88 years ± 16.76 [SD]; 18 female) and 45 participants with suspected arrhythmia (mean age, 53.21 years ± 15.45; 20 female), the AI-CS single-shot cine had better image quality compared with bSSFP cine, particularly in participants with arrhythmia (European Cardiovascular Magnetic Resonance Registry score: 0.32 ± 0.68 for bSSFP cine vs 0.05 ± 0.22 for AI-CS single-shot cine; <i>P</i> < .001), with fewer mistrigger events and cardiac motion artifacts. AI-CS showed good to excellent agreement with bSSFP for biventricular volume and LV mass measurements and provided comparable ejection fraction values to those at echocardiography in cases in which bSSFP failed (37.50% ± 5.28 vs 31.70% ± 6.43; <i>z</i> = -1.864; <i>P</i> = .06). Scan time was significantly reduced with AI-CS (10 seconds ± 2 vs 132 seconds ± 8; <i>P</i> < .001). Conclusion AI-CS single-shot cine demonstrated greater image quality and clinical feasibility compared with bFFSP cine in healthy participants and participants with suspected arrhythmias. <b>Keywords:</b> Artificial Intelligence-assisted Compressed SENSE, Arrhythmias, Left Ventricular Structure, Left Ventricular Function, Cardiac MRI, Balanced Steady-State Free Precession Cine Sequences <i>Supplemental material is available for this article.</i> © RSNA, 2026.

Radiology Cardiothoracic ImagingVol. 8(2)
Philips (China) (CN), Zhongshan Hospital (CN)
Quality Education
Openalex Percentile: Top 9%
Cardiac Imaging and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.