Optical Fibre Sensing for Monitoring Shallow Buried Utilities Under Dynamic Loading

The construction of urban light railway systems often requires costly diversion of buried utilities to mitigate potential damage from surface loads. However, understanding the behaviour of shallowly buried utility ducts due to dynamic loading is limited. This study investigated the structural behaviour of shallow buried utility pipes under cyclic loading (simulating tram loads). A 90 mm diameter high-density polyethylene (HDPE) pipe was buried at a depth of 300mm to the crown in a 10 m × 5.8 m x 5 m deep test pit at the National Buried Infrastructure Facility (NBIF), University of Birmingham, UK. To simulate a realistic surface track system, a reinforced concrete slab was constructed above the pipe to represent a tramway track bed. The pipe was offset by 600 mm from the edge of the track slab which was loaded using a 250kN dynamic actuator with dynamic loads ranging from 80–200 kN at frequencies of 1–8 Hz to simulate tram axle loads. Distributed optical fibre sensors (DOFS) were attached along the crown of the pipe and at three parallel circumferential positions. A Luna ODiSI 6100 interrogator was used to obtain dynamic, high-resolution strain measurements.<br/><br/>Results showed that pipe strains remained within the elastic range under simulated tram axle loads, with a maximum measured strain of 36.7 με. However, they exceeded predictions from the Spangler method in BS 9295, which assumes homogeneous, elastic soil and underestimates soil pressures and bending moments at shallow depths, especially under dynamic loading. The findings reveal limitations in conventional design codes and highlight the capability of DOFS to capture detailed strain distributions with high spatial and temporal resolution. This study underscores the value of large-scale controlled testing and integrating optical fibre sensing into geotechnical monitoring frameworks, supporting future research on ageing infrastructure and pipe materials.

Authors

Institutions

Publication Details

Journal
University of Birmingham Research Portal (University of Birmingham)
Published
2026-06-17
Primary Topic
Advanced Fiber Optic Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Fibre Sensing for Monitoring Shallow Buried Utilities Under Dynamic Loading

Nicole Metje, Harry Curtis, Sha Luo
University of Birmingham Research Portal (University of Birmingham)
Advanced Fiber Optic Sensors
article

Optical Fibre Sensing for Monitoring Shallow Buried Utilities Under Dynamic Loading

Nicole Metje, Harry Curtis, Sha Luo
article en

Abstract

The construction of urban light railway systems often requires costly diversion of buried utilities to mitigate potential damage from surface loads. However, understanding the behaviour of shallowly buried utility ducts due to dynamic loading is limited. This study investigated the structural behaviour of shallow buried utility pipes under cyclic loading (simulating tram loads). A 90 mm diameter high-density polyethylene (HDPE) pipe was buried at a depth of 300mm to the crown in a 10 m × 5.8 m x 5 m deep test pit at the National Buried Infrastructure Facility (NBIF), University of Birmingham, UK. To simulate a realistic surface track system, a reinforced concrete slab was constructed above the pipe to represent a tramway track bed. The pipe was offset by 600 mm from the edge of the track slab which was loaded using a 250kN dynamic actuator with dynamic loads ranging from 80–200 kN at frequencies of 1–8 Hz to simulate tram axle loads. Distributed optical fibre sensors (DOFS) were attached along the crown of the pipe and at three parallel circumferential positions. A Luna ODiSI 6100 interrogator was used to obtain dynamic, high-resolution strain measurements.<br/><br/>Results showed that pipe strains remained within the elastic range under simulated tram axle loads, with a maximum measured strain of 36.7 με. However, they exceeded predictions from the Spangler method in BS 9295, which assumes homogeneous, elastic soil and underestimates soil pressures and bending moments at shallow depths, especially under dynamic loading. The findings reveal limitations in conventional design codes and highlight the capability of DOFS to capture detailed strain distributions with high spatial and temporal resolution. This study underscores the value of large-scale controlled testing and integrating optical fibre sensing into geotechnical monitoring frameworks, supporting future research on ageing infrastructure and pipe materials.

University of Birmingham Research Portal (University of Birmingham)
Atkins (United States) (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 64%
Advanced Fiber Optic Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.