Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study

BACKGROUND Vibratory anesthetic devices (VADs) reduce dermatologic injection pain, but their vibration can feel harsh at sensitive anatomical sites. Simple modifications improving patient comfort may enhance VAD adoption. OBJECTIVE The authors evaluated whether dampening VAD vibration with a cotton buffer improves patient comfort and characterized tactile features influencing preferences. MATERIALS AND METHODS In a single-site, participant-blinded pilot study ( N = 53), adults received a dampened VAD (D-VAD) and standard VAD (S-VAD) at 5 sites—lateral nasal wall, submalar cheek, ear helix, lateral neck, and dorsal forearm—in randomized, contralateral application. Site-specific preference was analyzed with binomial and Cochran Q tests; demographic associations with univariate analyses. Word2vec and hierarchical clustering analyzed qualitative reasons behind patient preference. RESULTS D-VAD was preferred at all sites across demographics—lateral nasal wall (88.7%), submalar cheek (84.9%), ear helix (88.7%), lateral neck (77.4%), and dorsal forearm (75.5%) (all p < .001), with strongest preference at face and head/neck ( p = .018). Computational semantics analysis of qualitative responses identified 6 themes driving preference: Smoothness, Gentleness, Controlled, Low Frequency, Low Intensity, and Less Bothersome. CONCLUSION Dampening VAD vibration with a cotton buffer enhances comfort across sensitive sites, with reduced harshness and smoother sensation underlying preference. This simple modification may improve patient experience, encouraging broader VAD adoption.

Authors

Institutions

Publication Details

Journal
Dermatologic Surgery
Published
2026-03-23
DOI
https://doi.org/10.1097/dss.0000000000005078
Primary Topic
Dental Anxiety and Anesthesia Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study

Roberta L. Klatzky, Neha Gupta, Caroline M. Wilkowski, Arya Patel et al.
Dermatologic Surgery
Dental Anxiety and Anesthesia Techniques
article

Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study

Roberta L. Klatzky, Neha Gupta, Caroline M. Wilkowski, Arya Patel, Bryan T. Carroll
article en

Abstract

BACKGROUND Vibratory anesthetic devices (VADs) reduce dermatologic injection pain, but their vibration can feel harsh at sensitive anatomical sites. Simple modifications improving patient comfort may enhance VAD adoption. OBJECTIVE The authors evaluated whether dampening VAD vibration with a cotton buffer improves patient comfort and characterized tactile features influencing preferences. MATERIALS AND METHODS In a single-site, participant-blinded pilot study ( N = 53), adults received a dampened VAD (D-VAD) and standard VAD (S-VAD) at 5 sites—lateral nasal wall, submalar cheek, ear helix, lateral neck, and dorsal forearm—in randomized, contralateral application. Site-specific preference was analyzed with binomial and Cochran Q tests; demographic associations with univariate analyses. Word2vec and hierarchical clustering analyzed qualitative reasons behind patient preference. RESULTS D-VAD was preferred at all sites across demographics—lateral nasal wall (88.7%), submalar cheek (84.9%), ear helix (88.7%), lateral neck (77.4%), and dorsal forearm (75.5%) (all p < .001), with strongest preference at face and head/neck ( p = .018). Computational semantics analysis of qualitative responses identified 6 themes driving preference: Smoothness, Gentleness, Controlled, Low Frequency, Low Intensity, and Less Bothersome. CONCLUSION Dampening VAD vibration with a cotton buffer enhances comfort across sensitive sites, with reduced harshness and smoother sensation underlying preference. This simple modification may improve patient experience, encouraging broader VAD adoption.

Dermatologic Surgery
University Hospitals of Cleveland (US), University School (US), Case Western Reserve University (US), Carnegie Mellon University (US)
Openalex Percentile: Top 8%
Dental Anxiety and Anesthesia Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Improving Patient Comfort of Vibratory Anesthetic Devices With a Dampener: A Pilot Study — Roberta L. Klatzky, Neha Gupta, et al. · Dermatologic Surgery (2026) | TGRS Research Map | TGRS