Explainable deep learning framework for fecal contamination detection on chicken eggshells via portable fluorescence imaging under ambient light

This study evaluated the efficacy of optimized deep learning architectures using a portable fluorescence imaging device specifically for the in-situ detection of fecal contamination on chicken eggshells to enhance food safety. The research utilized a Contamination and Sanitization Inspection device to establish a comprehensive dataset of fluorescence images, leveraging the spectral characteristics of fecal matter which emits fluorescence in the 600 to 720 nm range. Based on this fluorescence image data set, the study developed high performance models to identify fecal residues across both brown and white eggshells. Experimental results demonstrated that the fluorescence signals of fecal contaminants remain highly stable under ambient lighting, with both the primary mode utilizing 405 nm excitation and the enhance mode utilizing 365 nm excitation achieving Structural Similarity Index Measure (SSIM) values consistently exceeding 0.9200. These metrics confirm that the intrinsic high contrast of fluorescence imaging maintains structural integrity without the need for strict darkroom environments. Through the evaluation of nine distinct neural networks, it was found that the 365 nm excitation effectively suppressed background interference on brown eggs, allowing the lightweight MobileNet architecture to detect fecal contamination with an accuracy of 0.9000. For white eggshells, the 405 nm excitation coupled with the ViT Base 384 model yielded a peak accuracy of 0.9333 in identifying minute fecal traces. The reliability of the detection was further validated through Explainable AI frameworks which confirmed that the classification logic was consistently based on actual contaminated regions marked by fecal residues. These findings provide a robust methodology for leveraging handheld portable fluorescence technology to establish objective standards for detecting fecal contamination in the poultry industry.

Authors

Institutions

Publication Details

Journal
Poultry Science
Published
2026-03-01
DOI
https://doi.org/10.1016/j.psj.2026.106868
Primary Topic
Cell Image Analysis Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Explainable deep learning framework for fecal contamination detection on chicken eggshells via portable fluorescence imaging under ambient light

Bradd J. Haley, Jianwei Qin, Fartash Vasefi, Chansong Hwang et al.
Poultry Science
Cell Image Analysis Techniques
article

Explainable deep learning framework for fecal contamination detection on chicken eggshells via portable fluorescence imaging under ambient light

Bradd J. Haley, Jianwei Qin, Fartash Vasefi, Chansong Hwang, Lalit Mohan Kandpal, Insuck Baek, Moon Kim, Mónica Santín, Sookyung Oh, Jitu Patel, Manan Sharma, Laura P. Del Collo
article en

Abstract

This study evaluated the efficacy of optimized deep learning architectures using a portable fluorescence imaging device specifically for the in-situ detection of fecal contamination on chicken eggshells to enhance food safety. The research utilized a Contamination and Sanitization Inspection device to establish a comprehensive dataset of fluorescence images, leveraging the spectral characteristics of fecal matter which emits fluorescence in the 600 to 720 nm range. Based on this fluorescence image data set, the study developed high performance models to identify fecal residues across both brown and white eggshells. Experimental results demonstrated that the fluorescence signals of fecal contaminants remain highly stable under ambient lighting, with both the primary mode utilizing 405 nm excitation and the enhance mode utilizing 365 nm excitation achieving Structural Similarity Index Measure (SSIM) values consistently exceeding 0.9200. These metrics confirm that the intrinsic high contrast of fluorescence imaging maintains structural integrity without the need for strict darkroom environments. Through the evaluation of nine distinct neural networks, it was found that the 365 nm excitation effectively suppressed background interference on brown eggs, allowing the lightweight MobileNet architecture to detect fecal contamination with an accuracy of 0.9000. For white eggshells, the 405 nm excitation coupled with the ViT Base 384 model yielded a peak accuracy of 0.9333 in identifying minute fecal traces. The reliability of the detection was further validated through Explainable AI frameworks which confirmed that the classification logic was consistently based on actual contaminated regions marked by fecal residues. These findings provide a robust methodology for leveraging handheld portable fluorescence technology to establish objective standards for detecting fecal contamination in the poultry industry.

Poultry Science
Agricultural Research Service (US), United States Department of Agriculture (US), Sherman Oaks Hospital (US), University of Maryland, Baltimore County (US)
Zero hunger
Openalex Percentile: Top 7%
Cell Image Analysis Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.