Innovative detection of methanol using a copper film–graphene–gold hybrid sensor engineered with 4-nitrothiophenol

We report the development of two novel methanol sensors based on copper film–supported graphene decorated with gold film. Electrode A (Cu/Gr-Au) was fabricated by depositing gold film on a graphene-coated copper film, while electrode B (Cu/Gr-Au-4-NTP) was prepared by further modifying this assembly with 4-nitrothiophenol (4-NTP). Advanced fabrication techniques enabled the preparation of these electrodes with excellent reproducibility and cost-effectiveness. Cyclic voltammetry measurements yielded a detection limit of 10 mM and a detection range of 10–485 mM for both electrode configurations, with sensitivities of 6.4 μA·mM −1 ·cm −2 for electrode A and 18.0 μA·mM −1 ·cm −2 for electrode B. Further electrochemical impedance spectroscopy studies (Z mod) confirmed a detection limit of 10 mM within a 10–485 mM range, with corresponding sensitivities of 0.147 Ω·mM −1 ·cm −2 for electrode A and 0.828 Ω·mM −1 ·cm −2 for electrode B. These findings demonstrate the enhanced performance of the 4-NTP functionalized electrode and underscore the potential of these innovative sensors for sensitive and rapid methanol detection compared to conventional systems. The enhanced performance of electrode B is attributed to the 4-NTP surface modification, which promotes methanol adsorption and facilitates electron transfer, resulting in superior sensitivity compared to electrode A. This work highlights the potential of integrating low-cost materials in sensor design to achieve high linearity, wide dynamic detection ranges, and rapid response times. The promising outcomes of these electrodes pave the way for further investigations into long-term stability, reproducibility, and system integration for real-time methanol monitoring applications. • Deposition of a 7.5 nm-thick Au film on graphene supported on Cu substrate. • Functionalization of the Au film by with 4-nitrothiophenol (4-NTP). • Electrochemical detection of methanol by the Au/Graphene/Cu and 4-NTP/Au/Graphene/Cu electrodes. • By CV measurements, detection limit of 10 mM and linear detection range of 10–485 mM. • Best sensitivity of 18.0 μA·mM −1 ·cm −2 .

Authors

Institutions

Publication Details

Journal
Microchemical Journal
Published
2026-03-01
DOI
https://doi.org/10.1016/j.microc.2026.117834
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovative detection of methanol using a copper film–graphene–gold hybrid sensor engineered with 4-nitrothiophenol

Francesco Ruffino, Antonino Scandurra, Stefano Boscarino, Hassan H. Hammud et al.
Microchemical Journal
Electrochemical sensors and biosensors
article

Innovative detection of methanol using a copper film–graphene–gold hybrid sensor engineered with 4-nitrothiophenol

Francesco Ruffino, Antonino Scandurra, Stefano Boscarino, Hassan H. Hammud, Hawra A. Bukhamsin, Chawki Awada
article en

Abstract

We report the development of two novel methanol sensors based on copper film–supported graphene decorated with gold film. Electrode A (Cu/Gr-Au) was fabricated by depositing gold film on a graphene-coated copper film, while electrode B (Cu/Gr-Au-4-NTP) was prepared by further modifying this assembly with 4-nitrothiophenol (4-NTP). Advanced fabrication techniques enabled the preparation of these electrodes with excellent reproducibility and cost-effectiveness. Cyclic voltammetry measurements yielded a detection limit of 10 mM and a detection range of 10–485 mM for both electrode configurations, with sensitivities of 6.4 μA·mM −1 ·cm −2 for electrode A and 18.0 μA·mM −1 ·cm −2 for electrode B. Further electrochemical impedance spectroscopy studies (Z mod) confirmed a detection limit of 10 mM within a 10–485 mM range, with corresponding sensitivities of 0.147 Ω·mM −1 ·cm −2 for electrode A and 0.828 Ω·mM −1 ·cm −2 for electrode B. These findings demonstrate the enhanced performance of the 4-NTP functionalized electrode and underscore the potential of these innovative sensors for sensitive and rapid methanol detection compared to conventional systems. The enhanced performance of electrode B is attributed to the 4-NTP surface modification, which promotes methanol adsorption and facilitates electron transfer, resulting in superior sensitivity compared to electrode A. This work highlights the potential of integrating low-cost materials in sensor design to achieve high linearity, wide dynamic detection ranges, and rapid response times. The promising outcomes of these electrodes pave the way for further investigations into long-term stability, reproducibility, and system integration for real-time methanol monitoring applications. • Deposition of a 7.5 nm-thick Au film on graphene supported on Cu substrate. • Functionalization of the Au film by with 4-nitrothiophenol (4-NTP). • Electrochemical detection of methanol by the Au/Graphene/Cu and 4-NTP/Au/Graphene/Cu electrodes. • By CV measurements, detection limit of 10 mM and linear detection range of 10–485 mM. • Best sensitivity of 18.0 μA·mM −1 ·cm −2 .

Microchemical Journal
University of Catania (IT), King Faisal University (SA)
Openalex Percentile: Top 8%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.