IoT Enable Electrical Safety in Organization

This system used to maintain and controlling earth resistance. The earth resistance is maintained by controlling moisture of earth using moisture sensor. Soil moisture sensor senses the moisture of the soil and gives data to the micro controller. If moisture decreases microcontroller operates motor through relay and water supplied to soil. we can see the status of moisture content of soil whether the moisture is present or not on (LCD). when any fault occurs the fault current flows through earthing and gets grounded, so in the proposed system instead of grounding the fault current we are storing that fault current in a battery through rectifier. And when battery gets fully charged then the battery gets disconnected by relay and fault current continues to flow from earthing to ground. The fully charged status of battery will sense by (vdc) and then it will give command to relay to disconnect the battery.

Authors

Institutions

Publication Details

Journal
INTERNATIONAL JOURNAL OF ENGINEERING DEVELOPMENT AND RESEARCH
Published
2026-03-01
DOI
https://doi.org/10.56975/ijedr.v14i1.305120
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

IoT Enable Electrical Safety in Organization

Deepak Kumar Chaurasiya, Lavkush Mishra, Manoj Kumar, Aishwarya Yadav et al.
INTERNATIONAL JOURNAL OF ENGINEERING DEVELOPMENT AND RESEARCH
Electrical Fault Detection and Protection
article

IoT Enable Electrical Safety in Organization

Deepak Kumar Chaurasiya, Lavkush Mishra, Manoj Kumar, Aishwarya Yadav, Atul Kumar Yadav
article en

Abstract

This system used to maintain and controlling earth resistance. The earth resistance is maintained by controlling moisture of earth using moisture sensor. Soil moisture sensor senses the moisture of the soil and gives data to the micro controller. If moisture decreases microcontroller operates motor through relay and water supplied to soil. we can see the status of moisture content of soil whether the moisture is present or not on (LCD). when any fault occurs the fault current flows through earthing and gets grounded, so in the proposed system instead of grounding the fault current we are storing that fault current in a battery through rectifier. And when battery gets fully charged then the battery gets disconnected by relay and fault current continues to flow from earthing to ground. The fully charged status of battery will sense by (vdc) and then it will give command to relay to disconnect the battery.

INTERNATIONAL JOURNAL OF ENGINEERING DEVELOPMENT AND RESEARCHVol. 14(1)
Institute of Technology Management (IN)
Life in Land
Openalex Percentile: Top 8%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.