Isocentric precision study on Shanghai Proton Therapy Device 360° compact gantry

<bold>Background</bold>Shanghai Advanced Proton Therapy Device (SAPT) is the first domestic proton therapy demonstration device, and the gantry is an important part of the proton therapy device, with an isocentric accuracy of ±0.275 mm, which is superior to most of the international mainstream equipments and requires high motion positioning accuracy and reliability.<bold>Purpose</bold>This study aims to provide a reference for the impact of the gantry structure on the treatment accuracy of the gantry of proton therapy device under different rotation angle conditions.<bold>Methods</bold>Firstly, the development progress of the 360° gantry for SAPT located in the Shanghai Ruijin Hospital proton center was introduced, and its isocentric accuracy was presented in detail. Then, deformation analysis of the gantry center point was carried out through the static structural analysis module of ANSYS. Finally, the actual deformation was measured using a laser tracker, and the error sphere was plotted to determine the accuracy at the center point under typical working conditions and analyze the causes.<bold>Results</bold>The qualitative analysis of the isocentric accuracy during the gantry rotation process shows that the trend of simulation results is consistent with the measured data (correlation coefficient <italic>R</italic><sup>2</sup> ≥ 0.92). The simulation predicts an overall isocentric accuracy of ±0.25 mm, while the measured result is ±0.275 mm, with a deviation rate &lt; 10%, which is superior to international mainstream equipment (typically &lt; ±1 mm). However, there is a certain deviation in the <italic>Z</italic>-axis direction (average deviation about 0.05 mm), which is attributed to mechanical installation errors not included in the simulation.<bold>Conclusions</bold>The simulation results of this study demonstrate that the stiffness, strength and stability of the gantry structure are at an excellent level, providing solid theoretical support for subsequent engineering applications. The successful development of China's first 360° gantry with ultra-high isocentric precision (±0.275 mm) represents not only a milestone in the localization of high-end medical equipment, but also achieves leading international level with innovative structure and cost advantages.

Authors

Publication Details

Journal
Nuclear Techniques
Published
2026-03-01
DOI
https://doi.org/10.3724/j.0253-3219.2026.hjs.49.250163
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Isocentric precision study on Shanghai Proton Therapy Device 360° compact gantry

Yunjing WANG, Wencheng FANG, Jun Wu, Zhentang ZHAO
Nuclear Techniques
Radiation Therapy and Dosimetry
article

Isocentric precision study on Shanghai Proton Therapy Device 360° compact gantry

Yunjing WANG, Wencheng FANG, Jun Wu, Zhentang ZHAO
article en

Abstract

<bold>Background</bold>Shanghai Advanced Proton Therapy Device (SAPT) is the first domestic proton therapy demonstration device, and the gantry is an important part of the proton therapy device, with an isocentric accuracy of ±0.275 mm, which is superior to most of the international mainstream equipments and requires high motion positioning accuracy and reliability.<bold>Purpose</bold>This study aims to provide a reference for the impact of the gantry structure on the treatment accuracy of the gantry of proton therapy device under different rotation angle conditions.<bold>Methods</bold>Firstly, the development progress of the 360° gantry for SAPT located in the Shanghai Ruijin Hospital proton center was introduced, and its isocentric accuracy was presented in detail. Then, deformation analysis of the gantry center point was carried out through the static structural analysis module of ANSYS. Finally, the actual deformation was measured using a laser tracker, and the error sphere was plotted to determine the accuracy at the center point under typical working conditions and analyze the causes.<bold>Results</bold>The qualitative analysis of the isocentric accuracy during the gantry rotation process shows that the trend of simulation results is consistent with the measured data (correlation coefficient <italic>R</italic><sup>2</sup> ≥ 0.92). The simulation predicts an overall isocentric accuracy of ±0.25 mm, while the measured result is ±0.275 mm, with a deviation rate &lt; 10%, which is superior to international mainstream equipment (typically &lt; ±1 mm). However, there is a certain deviation in the <italic>Z</italic>-axis direction (average deviation about 0.05 mm), which is attributed to mechanical installation errors not included in the simulation.<bold>Conclusions</bold>The simulation results of this study demonstrate that the stiffness, strength and stability of the gantry structure are at an excellent level, providing solid theoretical support for subsequent engineering applications. The successful development of China's first 360° gantry with ultra-high isocentric precision (±0.275 mm) represents not only a milestone in the localization of high-end medical equipment, but also achieves leading international level with innovative structure and cost advantages.

Nuclear TechniquesVol. 49(3)
Industry, innovation and infrastructure
Openalex Percentile: Top 9%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.