The simple model of helium filled Holtec’s Multi Purpose Container (MPC) for 37 spent fuel assemblies was developed and the calculation was performed using the Ansys Fluent code in steady state. The flow and temperature distribution within the MPC was calculated for different initial helium pressures, and for limiting cask heat loading found in the NPP Krsko SFDS (Spent Fuel Dry Storage) campaign number 1. The determined relationship between helium top to bottom temperature increase and helium pressure decrease can be used as a measure of cask leakage. In addition, lateral temperature distribution in the top MPC plenum, influenced partially by different spent fuel assembly loading, should be checked as a cause for temperature variation at the MPC external top surface, where RTD (Resistance Temperature Detector) detectors are installed.

Authors

Institutions

Publication Details

Journal
University of Zagreb University Computing Centre (SRCE)
Published
2026-01-01
DOI
https://doi.org/10.37798/2026751726
Primary Topic
Nuclear Materials and Properties
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Natural Heat Transfer Performance of Helium Filled Spent Fuel Multi Purpose Container Calculated for Different Initial Pressures

Nikola Novosel, Paulina Družijanić, Petra Strmečki, Davor Grgić
University of Zagreb University Computing Centre (SRCE)
Nuclear Materials and Properties
article

Natural Heat Transfer Performance of Helium Filled Spent Fuel Multi Purpose Container Calculated for Different Initial Pressures

Nikola Novosel, Paulina Družijanić, Petra Strmečki, Davor Grgić
article en

Abstract

The simple model of helium filled Holtec’s Multi Purpose Container (MPC) for 37 spent fuel assemblies was developed and the calculation was performed using the Ansys Fluent code in steady state. The flow and temperature distribution within the MPC was calculated for different initial helium pressures, and for limiting cask heat loading found in the NPP Krsko SFDS (Spent Fuel Dry Storage) campaign number 1. The determined relationship between helium top to bottom temperature increase and helium pressure decrease can be used as a measure of cask leakage. In addition, lateral temperature distribution in the top MPC plenum, influenced partially by different spent fuel assembly loading, should be checked as a cause for temperature variation at the MPC external top surface, where RTD (Resistance Temperature Detector) detectors are installed.

University of Zagreb University Computing Centre (SRCE)
University of Zagreb (HR)
Affordable and clean energy
Openalex Percentile: Top 10%
Nuclear Materials and Properties
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Natural Heat Transfer Performance of Helium Filled Spent Fuel Multi Purpose Container Calculated for Different Initial Pressures — Nikola Novosel, Paulina Družijanić, et al. · University of Zagreb University Computing Centre (SRCE) (2026) | TGRS Research Map | TGRS