Real-time continuous glucose monitoring with subcutaneously inserted sensor correlates better than subcutaneously implantable sensor with glycated hemoglobin, glycated albumin and fructosamine

These findings suggest that the Dexcom G6 and Guardian 4 systems more reliably reflect established biochemical markers of mid- to long-term glucose control, while Eversense may be less consistent in this regard. This highlights the importance of sensor selection when interpreting CGM data for clinical or research applications in diabetes management.

Authors

Institutions

Publication Details

Journal
Minerva Endocrinology
Published
2026-03-01
DOI
https://doi.org/10.23736/s2724-6507.26.04486-6
Primary Topic
Hyperglycemia and glycemic control in critically ill and hospitalized patients
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Real-time continuous glucose monitoring with subcutaneously inserted sensor correlates better than subcutaneously implantable sensor with glycated hemoglobin, glycated albumin and fructosamine

Michele Chicone, Sanja Medenica, Roberto Negro, Luigi E. GRECO et al.
Minerva Endocrinology
Hyperglycemia and glycemic control in critically ill and hospitalized patients
article

Real-time continuous glucose monitoring with subcutaneously inserted sensor correlates better than subcutaneously implantable sensor with glycated hemoglobin, glycated albumin and fructosamine

Michele Chicone, Sanja Medenica, Roberto Negro, Luigi E. GRECO, Djordje POPOVIC
article en

Abstract

These findings suggest that the Dexcom G6 and Guardian 4 systems more reliably reflect established biochemical markers of mid- to long-term glucose control, while Eversense may be less consistent in this regard. This highlights the importance of sensor selection when interpreting CGM data for clinical or research applications in diabetes management.

Minerva Endocrinology
University of Salento (IT), University of Novi Sad (RS), Klinički centar Vojvodine (RS), Ospedale Vito Fazzi (IT), University of Montenegro (ME)
Zero hunger
Openalex Percentile: Top 11%
Hyperglycemia and glycemic control in critically ill and hospitalized patients
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Real-time continuous glucose monitoring with subcutaneously inserted sensor correlates better than subcutaneously implantable sensor with glycated hemoglobin, glycated albumin and fructosamine — Michele Chicone, Sanja Medenica, et al. · Minerva Endocrinology (2026) | TGRS Research Map | TGRS