Summary of 15 Years of HVDC Experiments and Tests in Vacuum at the High-Voltage Padova Test Facilities

This article summarizes 15 years of experimental activity at the High-Voltage Padova Test Facilities in support of the design and commissioning of the ITER neutral beam injector (NBI). High-voltage DC tests up to 800 kV were carried out in high and medium vacuum on electrode gaps ranging from a few millimeters to 150 mm. Systematic experiments on stainless steel electrodes in high vacuum validated a probabilistic model for predicting the maximum hold-off voltage of generic multielectrode systems and confirmed the presence of a significant total-voltage effect for gap lengths above a few centimeters. The spatial distribution of power dissipation during microdischarges in large vacuum gaps suggests charge accumulation points and mutual charged-particle exchange between electrodes to interpret the experimental observations. Time-resolved X-ray measurements indicate that, in a significant fraction of vacuum breakdown events, bursts of electrons impacting the anode act as precursors, with electron-stimulated desorption playing a key role in discharge development and voltage collapse. In medium vacuum, tests in Ar, H<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, and N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> characterized the dependence of the hold-off voltage with pressure up to the left branch of the Paschen curve and clarified the influence of static magnetic fields on Townsend discharge. Long-duration tests under stationary electric fields up to 60 kV/mm revealed irreversible switch-on phenomena with microampere-level currents on short-gap configurations. Finally, acceptance tests on solid insulators, optical fibers, and spark gaps are reported, and the main lessons learned and open issues are discussed.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Plasma Science
Published
2026-01-01
DOI
https://doi.org/10.1109/tps.2026.3675427
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Summary of 15 Years of HVDC Experiments and Tests in Vacuum at the High-Voltage Padova Test Facilities

S. Spagnolo, F. Caruggi, A. Muraro, R. Gobbo et al.
IEEE Transactions on Plasma Science
HVDC Systems and Fault Protection
article

Summary of 15 Years of HVDC Experiments and Tests in Vacuum at the High-Voltage Padova Test Facilities

S. Spagnolo, F. Caruggi, A. Muraro, R. Gobbo, A. De Lorenzi, G. Chitarin, F. Guiotto, I. Mario, E. Spada, M. Agostini, Silvia Maria Deambrosis, N. Pilan, F. Pino, M. Fincato, N. Marconato, Cristiano Lino Fontana, G. Pesavento, M. Zuin, T. Patton, L. Lotto
article en

Abstract

This article summarizes 15 years of experimental activity at the High-Voltage Padova Test Facilities in support of the design and commissioning of the ITER neutral beam injector (NBI). High-voltage DC tests up to 800 kV were carried out in high and medium vacuum on electrode gaps ranging from a few millimeters to 150 mm. Systematic experiments on stainless steel electrodes in high vacuum validated a probabilistic model for predicting the maximum hold-off voltage of generic multielectrode systems and confirmed the presence of a significant total-voltage effect for gap lengths above a few centimeters. The spatial distribution of power dissipation during microdischarges in large vacuum gaps suggests charge accumulation points and mutual charged-particle exchange between electrodes to interpret the experimental observations. Time-resolved X-ray measurements indicate that, in a significant fraction of vacuum breakdown events, bursts of electrons impacting the anode act as precursors, with electron-stimulated desorption playing a key role in discharge development and voltage collapse. In medium vacuum, tests in Ar, H<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, and N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> characterized the dependence of the hold-off voltage with pressure up to the left branch of the Paschen curve and clarified the influence of static magnetic fields on Townsend discharge. Long-duration tests under stationary electric fields up to 60 kV/mm revealed irreversible switch-on phenomena with microampere-level currents on short-gap configurations. Finally, acceptance tests on solid insulators, optical fibers, and spark gaps are reported, and the main lessons learned and open issues are discussed.

IEEE Transactions on Plasma Science
University of Padua (IT), European Commission (BE), Istituto Nazionale di Fisica Nucleare, Sezione di Padova (IT), Gestione Sistemi per l’Informatica (Italy) (IT), Institute of Condensed Matter Chemistry and Technologies for Energy (IT), Joint Research Center (BE), Institute for the Science and Technology of Plasmas (IT), University of Milano-Bicocca (IT)
Affordable and clean energy
Openalex Percentile: Top 9%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.