Summary of 15 Years of HVDC Experiments and Tests in Vacuum at the High-Voltage Padova Test Facilities
This article summarizes 15 years of experimental activity at the High-Voltage Padova Test Facilities in support of the design and commissioning of the ITER neutral beam injector (NBI). High-voltage DC tests up to 800 kV were carried out in high and medium vacuum on electrode gaps ranging from a few millimeters to 150 mm. Systematic experiments on stainless steel electrodes in high vacuum validated a probabilistic model for predicting the maximum hold-off voltage of generic multielectrode systems and confirmed the presence of a significant total-voltage effect for gap lengths above a few centimeters. The spatial distribution of power dissipation during microdischarges in large vacuum gaps suggests charge accumulation points and mutual charged-particle exchange between electrodes to interpret the experimental observations. Time-resolved X-ray measurements indicate that, in a significant fraction of vacuum breakdown events, bursts of electrons impacting the anode act as precursors, with electron-stimulated desorption playing a key role in discharge development and voltage collapse. In medium vacuum, tests in Ar, H<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub>, and N<sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> characterized the dependence of the hold-off voltage with pressure up to the left branch of the Paschen curve and clarified the influence of static magnetic fields on Townsend discharge. Long-duration tests under stationary electric fields up to 60 kV/mm revealed irreversible switch-on phenomena with microampere-level currents on short-gap configurations. Finally, acceptance tests on solid insulators, optical fibers, and spark gaps are reported, and the main lessons learned and open issues are discussed.
Authors
- S. Spagnolo
- F. Caruggi (ORCID: https://orcid.org/0000-0002-5480-1327)
- A. Muraro (ORCID: https://orcid.org/0000-0002-4570-4576)
- R. Gobbo
- A. De Lorenzi (ORCID: https://orcid.org/0000-0002-5647-3419)
- G. Chitarin (ORCID: https://orcid.org/0000-0003-3060-8466)
- F. Guiotto (ORCID: https://orcid.org/0000-0001-6014-918X)
- I. Mario (ORCID: https://orcid.org/0000-0001-8778-4191)
- E. Spada (ORCID: https://orcid.org/0000-0003-4770-303X)
- M. Agostini (ORCID: https://orcid.org/0000-0002-3823-1002)
- Silvia Maria Deambrosis (ORCID: https://orcid.org/0000-0002-3186-232X)
- N. Pilan
- F. Pino (ORCID: https://orcid.org/0000-0002-3224-0493)
- M. Fincato
- N. Marconato (ORCID: https://orcid.org/0000-0003-0452-5456)
- Cristiano Lino Fontana (ORCID: https://orcid.org/0000-0003-4863-0880)
- G. Pesavento
- M. Zuin (ORCID: https://orcid.org/0000-0002-0282-2978)
- T. Patton (ORCID: https://orcid.org/0000-0001-6512-0984)
- L. Lotto
Institutions
- University of Padua (IT)
- European Commission (BE)
- Istituto Nazionale di Fisica Nucleare, Sezione di Padova (IT)
- Gestione Sistemi per l’Informatica (Italy) (IT)
- Institute of Condensed Matter Chemistry and Technologies for Energy (IT)
- Joint Research Center (BE)
- Institute for the Science and Technology of Plasmas (IT)
- University of Milano-Bicocca (IT)
Publication Details
- Journal
- IEEE Transactions on Plasma Science
- Published
- 2026-01-01
- DOI
- https://doi.org/10.1109/tps.2026.3675427
- Primary Topic
- HVDC Systems and Fault Protection
- Type
- article
- Field-Weighted Citation Impact
- 0.00