Ventilation performance of a novel multi-mode fume hood with supply air on contaminant with different densities

A multi-mode air-supply fume hood was designed to effectively remove contaminants of varying densities within the cabinet by altering the position and angle of the air supply. Numerical simulation methods were employed to analyse the performance of heavy-density and light-density modes in handling contaminants of different densities and to evaluate the impact of the airflow distribution on contaminant removal efficiency. The study demonstrates that optimised designs can reduce the leakage rate of the fume hood, enhancing its performance and efficiency. In heavy-density mode, increasing air supply effectively reduces room air conditioning load and building energy consumption, with a downward vertical air supply angle and a 70% air supply-exhaust ratio providing higher safety. In light-density mode, a vertically downward air supply angle offers better safety, and a downward air curtain at the lower end of the operating door is more effective in controlling contaminant leakage compared to a bottom slit air supply. The average concentration of contaminants in the fume hood was reduced by 35.98% at a 60% supply-to-exhaust ratio.

Institutions

Publication Details

Journal
Indoor and Built Environment
Published
2026-03-24
DOI
https://doi.org/10.1177/1420326x261429389
Primary Topic
Infection Control and Ventilation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventilation performance of a novel multi-mode fume hood with supply air on contaminant with different densities

Indoor and Built Environment
Infection Control and Ventilation
article

Ventilation performance of a novel multi-mode fume hood with supply air on contaminant with different densities

article en

Abstract

A multi-mode air-supply fume hood was designed to effectively remove contaminants of varying densities within the cabinet by altering the position and angle of the air supply. Numerical simulation methods were employed to analyse the performance of heavy-density and light-density modes in handling contaminants of different densities and to evaluate the impact of the airflow distribution on contaminant removal efficiency. The study demonstrates that optimised designs can reduce the leakage rate of the fume hood, enhancing its performance and efficiency. In heavy-density mode, increasing air supply effectively reduces room air conditioning load and building energy consumption, with a downward vertical air supply angle and a 70% air supply-exhaust ratio providing higher safety. In light-density mode, a vertically downward air supply angle offers better safety, and a downward air curtain at the lower end of the operating door is more effective in controlling contaminant leakage compared to a bottom slit air supply. The average concentration of contaminants in the fume hood was reduced by 35.98% at a 60% supply-to-exhaust ratio.

Indoor and Built Environment
University of Shanghai for Science and Technology (CN), China Tobacco (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
Infection Control and Ventilation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.