Quantitative Mechanical Profiling of Twelve ERCP Guidewires: Toward Evidence-Based Device Selection

Abstract Background and Aims: Numerous guidewires are available for ERCP and interventional EUS, each with distinct mechanical characteristics. While individual features such as tip flexibility or shaft stiffness have been studied, no prior research has comprehensively compared multiple guidewires. This study aimed to quantitatively and visually characterize the mechanical properties of guidewires using a standardized bench-top evaluation framework. Methods: Twelve guidewires available in Japan were tested. Seven mechanical parameters were assessed: tip load, maximum tip load, front and rear shaft stiffness, torque performance, whip performance, and radiographic visibility. All tests were conducted under standardized conditions using dedicated equipment. Performance scores were normalized (1–10 scale), and radar charts were generated for visualization. Results: Guidewires showed wide variability across parameters. Tip load ranged from 0.026±0.029 to 0.114±0.025 N; maximum tip load from 0.180±0.040 to 0.697±0.059 N. Shaft stiffness ranged from 0 to 0.343±0.006 N (front) and 0.057±0.006 to 0.477±0.006 N (rear). Torque deviation ranged from 19.6±16.7° to 41.0±23.8°; whip performance from 13.5±0.6 to 163.4±77.6 °/sec. Radiographic contrast ranged from 292.7 to 1125.4. Values are mean ± SD unless otherwise stated; radiographic contrast was measured once. Radar chart shapes were classified into four types: Bowl, Rightward, Leftward, and Upward. Radar chart visualization revealed distinct mechanical profile patterns among guidewires. Conclusions: This is the first study to provide integrated mechanical profiles of ERCP and EUS guidewires based on standardized bench-top testing. Radar chart visualization offers an intuitive framework for comparing relative mechanical tendencies and may serve as a useful reference for research and education.

Institutions

Publication Details

Journal
Endoscopy International Open
Published
2026-03-24
DOI
https://doi.org/10.1055/a-2840-7390
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Quantitative Mechanical Profiling of Twelve ERCP Guidewires: Toward Evidence-Based Device Selection

Endoscopy International Open
Surgical Simulation and Training
article

Quantitative Mechanical Profiling of Twelve ERCP Guidewires: Toward Evidence-Based Device Selection

article en

Abstract

Abstract Background and Aims: Numerous guidewires are available for ERCP and interventional EUS, each with distinct mechanical characteristics. While individual features such as tip flexibility or shaft stiffness have been studied, no prior research has comprehensively compared multiple guidewires. This study aimed to quantitatively and visually characterize the mechanical properties of guidewires using a standardized bench-top evaluation framework. Methods: Twelve guidewires available in Japan were tested. Seven mechanical parameters were assessed: tip load, maximum tip load, front and rear shaft stiffness, torque performance, whip performance, and radiographic visibility. All tests were conducted under standardized conditions using dedicated equipment. Performance scores were normalized (1–10 scale), and radar charts were generated for visualization. Results: Guidewires showed wide variability across parameters. Tip load ranged from 0.026±0.029 to 0.114±0.025 N; maximum tip load from 0.180±0.040 to 0.697±0.059 N. Shaft stiffness ranged from 0 to 0.343±0.006 N (front) and 0.057±0.006 to 0.477±0.006 N (rear). Torque deviation ranged from 19.6±16.7° to 41.0±23.8°; whip performance from 13.5±0.6 to 163.4±77.6 °/sec. Radiographic contrast ranged from 292.7 to 1125.4. Values are mean ± SD unless otherwise stated; radiographic contrast was measured once. Radar chart shapes were classified into four types: Bowl, Rightward, Leftward, and Upward. Radar chart visualization revealed distinct mechanical profile patterns among guidewires. Conclusions: This is the first study to provide integrated mechanical profiles of ERCP and EUS guidewires based on standardized bench-top testing. Radar chart visualization offers an intuitive framework for comparing relative mechanical tendencies and may serve as a useful reference for research and education.

Endoscopy International Open
Suzuka University of Medical Science (JP), Mie University Hospital (JP)
Quality Education
Openalex Percentile: Top 10%
Surgical Simulation and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Quantitative Mechanical Profiling of Twelve ERCP Guidewires: Toward Evidence-Based Device Selection · Endoscopy International Open (2026) | TGRS Research Map | TGRS