Target-based multi-objective retrofit design of nZEB school buildings using room-specific indoor environmental quality requirements

• Proposes a target-based retrofit framework for multi-zone school buildings • Optimizes energy use, indoor CO 2 levels, comfort, and retrofit costs • Integrates IDA-ICE simulations, surrogates, and NSGA-III optimization • Constrains worst-performing rooms instead of building-wide averages • Identifies nZEB-compliant solutions with CO 2 < 800 ppm and PPD ≤ 10% Retrofit design for nearly zero emission (nZEB) school buildings must reconcile strict energy targets with healthy, comfortable indoor environments. Most multi-objective retrofit studies either model a single representative zone or optimise building-average indicators, which can mask rooms with poor indoor air quality (IAQ) or thermal comfort. In a Norwegian agricultural school, baseline simulations show that building-average CO₂ and predicted percentage dissatisfied (PPD) meet common design targets, while several rooms exceed IAQ and comfort thresholds.We propose a target-based multi-objective optimisation framework that explicitly constrains the worst-performing rooms. Four objectives are considered: annual specific energy use, maximum room CO₂, maximum room PPD, and total retrofit investment cost. Energy use is constrained to the Norwegian nZEB limit for schools (≤ 91 kWh/(m²·y)), with CO₂ and PPD limited to 800 ppm and 10 %, in line with EN 16798 and recent IAQ guidance. Eight design variables (envelope U-values, supply-air temperature setpoints, infiltration, and ventilation rates) are explored using a Definitive Screening Design with 17 IDA-ICE simulations and second-order surrogate models (R² ≥ 0.99). These feed an NSGA-III algorithm to generate a Pareto front, which is post-processed with an Entropy–TOPSIS method to rank solutions. Results show that retrofit strategies can keep every room below 800 ppm CO₂ and 10 % PPD while satisfying the nZEB energy limit at moderate investment levels. The framework is generic and transferable, providing transparent decision support that shifts from building-average metrics toward room-specific occupant protection.

Institutions

Publication Details

Journal
Building and Environment
Published
2026-03-24
DOI
https://doi.org/10.1016/j.buildenv.2026.114546
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Target-based multi-objective retrofit design of nZEB school buildings using room-specific indoor environmental quality requirements

Building and Environment
Building Energy and Comfort Optimization
article

Target-based multi-objective retrofit design of nZEB school buildings using room-specific indoor environmental quality requirements

article en

Abstract

• Proposes a target-based retrofit framework for multi-zone school buildings • Optimizes energy use, indoor CO 2 levels, comfort, and retrofit costs • Integrates IDA-ICE simulations, surrogates, and NSGA-III optimization • Constrains worst-performing rooms instead of building-wide averages • Identifies nZEB-compliant solutions with CO 2 < 800 ppm and PPD ≤ 10% Retrofit design for nearly zero emission (nZEB) school buildings must reconcile strict energy targets with healthy, comfortable indoor environments. Most multi-objective retrofit studies either model a single representative zone or optimise building-average indicators, which can mask rooms with poor indoor air quality (IAQ) or thermal comfort. In a Norwegian agricultural school, baseline simulations show that building-average CO₂ and predicted percentage dissatisfied (PPD) meet common design targets, while several rooms exceed IAQ and comfort thresholds.We propose a target-based multi-objective optimisation framework that explicitly constrains the worst-performing rooms. Four objectives are considered: annual specific energy use, maximum room CO₂, maximum room PPD, and total retrofit investment cost. Energy use is constrained to the Norwegian nZEB limit for schools (≤ 91 kWh/(m²·y)), with CO₂ and PPD limited to 800 ppm and 10 %, in line with EN 16798 and recent IAQ guidance. Eight design variables (envelope U-values, supply-air temperature setpoints, infiltration, and ventilation rates) are explored using a Definitive Screening Design with 17 IDA-ICE simulations and second-order surrogate models (R² ≥ 0.99). These feed an NSGA-III algorithm to generate a Pareto front, which is post-processed with an Entropy–TOPSIS method to rank solutions. Results show that retrofit strategies can keep every room below 800 ppm CO₂ and 10 % PPD while satisfying the nZEB energy limit at moderate investment levels. The framework is generic and transferable, providing transparent decision support that shifts from building-average metrics toward room-specific occupant protection.

Building and EnvironmentVol. 296
University of Sarajevo (BA), OsloMet – Oslo Metropolitan University (NO), UiT The Arctic University of Norway (NO)
Openalex Percentile: Top 10%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.