Detecting Occlusion Myocardial Infarction with an AI-Powered ECG Model: A Retrospective Cohort Study

Background: Patients with NSTEMI who are found with a totally occluded culprit vessel on coronary angiography are at higher risk of mortality and major adverse cardiac events. Artificial intelligence (AI) models can help identify this subgroup of NSTEMIs. Objectives: The purpose of this study was to examine the performance of an AI model in identifying patients with total thrombotic coronary artery occlusion myocardial infarctions (OMIs) using a single 12-lead ECG as input. Methods: In this retrospective cohort study, 12-lead ECGs corresponding to patients with suspected OMI were analyzed by an AI model. Confirmation of OMI was based on angiographic evidence of acute culprit coronary artery stenosis. Results: Over a one-year period, emergency physicians at our hospital identified 474 patients with suspected OMI, of whom 88 met STEMI criteria. Out of the 142 angiographically confirmed OMIs, the AI model correctly identified 115 (81%) with high confidence, corresponding to an accuracy of 89.4%, sensitivity of 90.0%, specificity of 93.2%, positive predictive value (PPV) of 84.6%, and negative predictive value (NPV) of 91.4%. Out of the 74 angiographically confirmed OMIs that did not meet STEMI criteria, the AI model correctly identified 49 (66%) with high confidence, corresponding to an accuracy of 87.9%, sensitivity of 66.2%, specificity of 93.4%, PPV of 72.1%, and NPV of 91.5%. Out of the 68 angiographically confirmed OMIs that met STEMI criteria, the AI model correctly identified 66 (97%) with high confidence, corresponding to an accuracy of 95.5%, sensitivity of 97.1%, specificity of 90.0%, PPV of 97.1%, and NPV of 90.0%. Conclusions: The AI model examined in this study outperformed the STEMI criteria for the identification of OMI with respect to accuracy, sensitivity, specificity, PPV, and NPV and accurately identified a significant portion of NSTEMIs found to have total thrombotic coronary artery occlusion.

Institutions

Publication Details

Journal
Journal of Personalized Medicine
Published
2026-03-24
DOI
https://doi.org/10.3390/jpm16040174
Primary Topic
Acute Myocardial Infarction Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Detecting Occlusion Myocardial Infarction with an AI-Powered ECG Model: A Retrospective Cohort Study

Journal of Personalized Medicine
Acute Myocardial Infarction Research
article

Detecting Occlusion Myocardial Infarction with an AI-Powered ECG Model: A Retrospective Cohort Study

article en

Abstract

Background: Patients with NSTEMI who are found with a totally occluded culprit vessel on coronary angiography are at higher risk of mortality and major adverse cardiac events. Artificial intelligence (AI) models can help identify this subgroup of NSTEMIs. Objectives: The purpose of this study was to examine the performance of an AI model in identifying patients with total thrombotic coronary artery occlusion myocardial infarctions (OMIs) using a single 12-lead ECG as input. Methods: In this retrospective cohort study, 12-lead ECGs corresponding to patients with suspected OMI were analyzed by an AI model. Confirmation of OMI was based on angiographic evidence of acute culprit coronary artery stenosis. Results: Over a one-year period, emergency physicians at our hospital identified 474 patients with suspected OMI, of whom 88 met STEMI criteria. Out of the 142 angiographically confirmed OMIs, the AI model correctly identified 115 (81%) with high confidence, corresponding to an accuracy of 89.4%, sensitivity of 90.0%, specificity of 93.2%, positive predictive value (PPV) of 84.6%, and negative predictive value (NPV) of 91.4%. Out of the 74 angiographically confirmed OMIs that did not meet STEMI criteria, the AI model correctly identified 49 (66%) with high confidence, corresponding to an accuracy of 87.9%, sensitivity of 66.2%, specificity of 93.4%, PPV of 72.1%, and NPV of 91.5%. Out of the 68 angiographically confirmed OMIs that met STEMI criteria, the AI model correctly identified 66 (97%) with high confidence, corresponding to an accuracy of 95.5%, sensitivity of 97.1%, specificity of 90.0%, PPV of 97.1%, and NPV of 90.0%. Conclusions: The AI model examined in this study outperformed the STEMI criteria for the identification of OMI with respect to accuracy, sensitivity, specificity, PPV, and NPV and accurately identified a significant portion of NSTEMIs found to have total thrombotic coronary artery occlusion.

Journal of Personalized MedicineVol. 16(4)
North Shore University Hospital (US), Stony Brook University (US)
Good health and well-being
Openalex Percentile: Top 20%
Acute Myocardial Infarction Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Detecting Occlusion Myocardial Infarction with an AI-Powered ECG Model: A Retrospective Cohort Study · Journal of Personalized Medicine (2026) | TGRS Research Map | TGRS