Noncontact Current Measurement Method for Multicore Cables Considering Nonlinear Effects of Steel Tape Armor

Steel tape armored multicore cables are critical components in the transmission and distribution of power in medium- and low-voltage networks. It is difficult to measure current in the individual conductors of multicore cables because they are enclosed within multilayer protective structures (e.g., armor). The magnetic field–current inversion method provides a noncontact alternative for measuring conductor currents, derived from externally measured magnetic fields. However, the nonlinear magnetization effects of the steel tape armor disrupt the linear relationship between the magnetic field and currents, making accurate measurements challenging. To address this issue, we propose a noncontact current measurement method that incorporates the nonlinear effects of the armor layer. This method involves pre-calibrating the coefficient matrices, determining the angle formed between the magnetic sensor array and the multicore cable, and applying nonlinear fitting. This achieves a current measurement accuracy less than 5% and 5° in relative error and phase error, respectively. The proposed method avoids computationally intensive inverse operations, thereby enabling the realization of lightweight, low-cost current measurement terminals for practical field applications.

Institutions

Publication Details

Journal
Energies
Published
2026-03-24
DOI
https://doi.org/10.3390/en19071594
Primary Topic
Magnetic Field Sensors Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noncontact Current Measurement Method for Multicore Cables Considering Nonlinear Effects of Steel Tape Armor

Energies
Magnetic Field Sensors Techniques
article

Noncontact Current Measurement Method for Multicore Cables Considering Nonlinear Effects of Steel Tape Armor

article en

Abstract

Steel tape armored multicore cables are critical components in the transmission and distribution of power in medium- and low-voltage networks. It is difficult to measure current in the individual conductors of multicore cables because they are enclosed within multilayer protective structures (e.g., armor). The magnetic field–current inversion method provides a noncontact alternative for measuring conductor currents, derived from externally measured magnetic fields. However, the nonlinear magnetization effects of the steel tape armor disrupt the linear relationship between the magnetic field and currents, making accurate measurements challenging. To address this issue, we propose a noncontact current measurement method that incorporates the nonlinear effects of the armor layer. This method involves pre-calibrating the coefficient matrices, determining the angle formed between the magnetic sensor array and the multicore cable, and applying nonlinear fitting. This achieves a current measurement accuracy less than 5% and 5° in relative error and phase error, respectively. The proposed method avoids computationally intensive inverse operations, thereby enabling the realization of lightweight, low-cost current measurement terminals for practical field applications.

EnergiesVol. 19(7)
China Southern Power Grid (China) (CN), Tsinghua University (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
Magnetic Field Sensors Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.