Evaluation of air purifier and fan installation heights for enhancing indoor air quality in a plastic greenhouse

Plastic greenhouses, widely adopted due to low cost and flexibility, often rely on natural ventilation, which can cause heat accumulation and the buildup of airborne pathogens and harmful gases. This study evaluated the influence of installation height of air purifiers and circulation fans on indoor air quality (IAQ) in a plastic greenhouse using CFD simulations. Device heights and operating conditions were varied, and IAQ was assessed through age of air. The CFD model was validated against measured indoor temperature data, yielding a mean absolute percentage error of 3.9%. A sensitivity analysis confirmed robustness, as variations in outdoor air temperature (±1°C), ground temperature (±1°C) and solar radiation (±10%) caused prediction variations of about ±1.6%, ±1.5% and ±1.0%, respectively. During daytime, placing air purifiers at 2.6 m and circulation fans at 4.0 m minimized the age of air and suppressed thermal stratification, while at nighttime favourable IAQ was maintained even without fan operation. Compared with less effective setups, the recommended configuration reduced the age of air by approximately 21%. These results suggest an energy-efficient strategy in which both devices are operated during the day and only the purifiers at night, providing practical guidance for low-cost IAQ management in plastic greenhouses.

Publication Details

Journal
Indoor and Built Environment
Published
2026-03-24
DOI
https://doi.org/10.1177/1420326x261424113
Primary Topic
Greenhouse Technology and Climate Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of air purifier and fan installation heights for enhancing indoor air quality in a plastic greenhouse

Indoor and Built Environment
Greenhouse Technology and Climate Control
article

Evaluation of air purifier and fan installation heights for enhancing indoor air quality in a plastic greenhouse

article en

Abstract

Plastic greenhouses, widely adopted due to low cost and flexibility, often rely on natural ventilation, which can cause heat accumulation and the buildup of airborne pathogens and harmful gases. This study evaluated the influence of installation height of air purifiers and circulation fans on indoor air quality (IAQ) in a plastic greenhouse using CFD simulations. Device heights and operating conditions were varied, and IAQ was assessed through age of air. The CFD model was validated against measured indoor temperature data, yielding a mean absolute percentage error of 3.9%. A sensitivity analysis confirmed robustness, as variations in outdoor air temperature (±1°C), ground temperature (±1°C) and solar radiation (±10%) caused prediction variations of about ±1.6%, ±1.5% and ±1.0%, respectively. During daytime, placing air purifiers at 2.6 m and circulation fans at 4.0 m minimized the age of air and suppressed thermal stratification, while at nighttime favourable IAQ was maintained even without fan operation. Compared with less effective setups, the recommended configuration reduced the age of air by approximately 21%. These results suggest an energy-efficient strategy in which both devices are operated during the day and only the purifiers at night, providing practical guidance for low-cost IAQ management in plastic greenhouses.

Indoor and Built Environment
Affordable and clean energy
Openalex Percentile: Top 10%
Greenhouse Technology and Climate Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.