Performance of the new Laryngeal Tube LT®evo during simulated resuscitation: a randomised crossover manikin study

Effective airway management is essential for high-quality cardiopulmonary resuscitation (CPR). While tracheal intubation (TI) has traditionally been regarded as the reference technique for advanced airway management, it requires substantial expertise and may prolong no-flow time during CPR. Current European Resuscitation Council (ERC) guidelines recommend the i-gel® as the preferred supraglottic airway (SGA). The newly developed Laryngeal Tube LT®evo (VBM Medizintechnik, Germany) was designed to simplify insertion and improve ventilation performance. This study evaluated its efficacy compared with bag-valve-mask-ventilation (BVM) and tracheal intubation (TI) in a standardized resuscitation scenario. In this prospective, randomised crossover manikin study, 20 anaesthesiologists with varying experience in prehospital and in-hospital Airway management during CPR performed three resuscitation scenarios using BVM, TI, or LT®evo in random order. Each 5-minute scenario simulated a cardiac arrest with initial shockable rhythm and required up to three mandatory defibrillations. The primary endpoint was total no-flow time. Secondary endpoints included device insertion time, time-to-first-effective-ventilation (tidal-volume ≥ 400 mL), and number of insufficient ventilations. All 60 simulations were completed. Compared with LT®evo, BVM produced statistically longer no-flow time (regression coefficient [RC] = 4.00; 95%-CI = 0.13–7.87), a higher rate of insufficient ventilations (RC = 1.25; 95%CI = 0.44–2.09), and lower tidal-volumes (RC = − 66.05; 95%CI = − 124.75- −7.35). Compared to LT®evo, there was no evidence for a difference in no-flow time for TI (RC = − 2.17; 95%CI = − 6.04–1.70) in experienced users. In this first evaluation of the LT®evo, the device enabled rapid, effective ventilation with minimal interruption of chest compressions. Its ease of use and observed performance characteristics support further clinical investigation as potential alternative SGA for resuscitation.

Institutions

Publication Details

Journal
International Journal of Emergency Medicine
Published
2026-03-24
DOI
https://doi.org/10.1186/s12245-026-01163-8
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance of the new Laryngeal Tube LT®evo during simulated resuscitation: a randomised crossover manikin study

International Journal of Emergency Medicine
Airway Management and Intubation Techniques
article

Performance of the new Laryngeal Tube LT®evo during simulated resuscitation: a randomised crossover manikin study

article en

Abstract

Effective airway management is essential for high-quality cardiopulmonary resuscitation (CPR). While tracheal intubation (TI) has traditionally been regarded as the reference technique for advanced airway management, it requires substantial expertise and may prolong no-flow time during CPR. Current European Resuscitation Council (ERC) guidelines recommend the i-gel® as the preferred supraglottic airway (SGA). The newly developed Laryngeal Tube LT®evo (VBM Medizintechnik, Germany) was designed to simplify insertion and improve ventilation performance. This study evaluated its efficacy compared with bag-valve-mask-ventilation (BVM) and tracheal intubation (TI) in a standardized resuscitation scenario. In this prospective, randomised crossover manikin study, 20 anaesthesiologists with varying experience in prehospital and in-hospital Airway management during CPR performed three resuscitation scenarios using BVM, TI, or LT®evo in random order. Each 5-minute scenario simulated a cardiac arrest with initial shockable rhythm and required up to three mandatory defibrillations. The primary endpoint was total no-flow time. Secondary endpoints included device insertion time, time-to-first-effective-ventilation (tidal-volume ≥ 400 mL), and number of insufficient ventilations. All 60 simulations were completed. Compared with LT®evo, BVM produced statistically longer no-flow time (regression coefficient [RC] = 4.00; 95%-CI = 0.13–7.87), a higher rate of insufficient ventilations (RC = 1.25; 95%CI = 0.44–2.09), and lower tidal-volumes (RC = − 66.05; 95%CI = − 124.75- −7.35). Compared to LT®evo, there was no evidence for a difference in no-flow time for TI (RC = − 2.17; 95%CI = − 6.04–1.70) in experienced users. In this first evaluation of the LT®evo, the device enabled rapid, effective ventilation with minimal interruption of chest compressions. Its ease of use and observed performance characteristics support further clinical investigation as potential alternative SGA for resuscitation.

International Journal of Emergency MedicineVol. 19(1)
Bielefeld University (DE), Heidelberg University (DE), University Hospital Heidelberg (DE), Institut Pasteur de la Guadeloupe (GP), Johannes Wesling Klinikum Minden (DE)
Openalex Percentile: Top 11%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.