Biomechanical evaluation of load-bearing performance and primary stability in a novel transhumeral osseointegrated prosthesis: a finite element analysis

After humeral amputation, patients often struggle to handle medium to heavy loads. Conventional hollow socket prostheses remain insufficient for such demands. This study proposes an innovative transhumeral osseointegrated prosthesis design, evaluated using a three-dimensional finite element model under five static loads (25-300 N) with Bio-steel and Ti-6Al-4V implants. Stresses in cancellous bone remained well below compressive strength limits (≤1.11 MPa), even at maximum loading. Implant displacements were minimal (<0.63 mm), indicating high primary stability. These results confirm the model's mechanical validity and support this prosthesis as a safe and effective load-bearing alternative for upper-limb amputees.

Publication Details

Journal
Computer Methods in Biomechanics & Biomedical Engineering
Published
2026-03-23
DOI
https://doi.org/10.1080/10255842.2026.2647113
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Biomechanical evaluation of load-bearing performance and primary stability in a novel transhumeral osseointegrated prosthesis: a finite element analysis

Computer Methods in Biomechanics & Biomedical Engineering
Prosthetics and Rehabilitation Robotics
article

Biomechanical evaluation of load-bearing performance and primary stability in a novel transhumeral osseointegrated prosthesis: a finite element analysis

article en

Abstract

After humeral amputation, patients often struggle to handle medium to heavy loads. Conventional hollow socket prostheses remain insufficient for such demands. This study proposes an innovative transhumeral osseointegrated prosthesis design, evaluated using a three-dimensional finite element model under five static loads (25-300 N) with Bio-steel and Ti-6Al-4V implants. Stresses in cancellous bone remained well below compressive strength limits (≤1.11 MPa), even at maximum loading. Implant displacements were minimal (<0.63 mm), indicating high primary stability. These results confirm the model's mechanical validity and support this prosthesis as a safe and effective load-bearing alternative for upper-limb amputees.

Computer Methods in Biomechanics & Biomedical Engineering
Openalex Percentile: Top 11%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.