Covered Self-Expandable Metallic Stents versus Multiple Plastic Stents for Benign Biliary Strictures: A Systematic Review, Meta-Analysis, and Trial Sequential Analysis

Abstract We aim to compare the benefits, harms, and costs of multiple plastic stents (MPS) versus covered self-expandable metallic stents (CSEMS) in the treatment of benign biliary strictures (BBS). A comprehensive database search through June 6, 2024 identified randomized controlled trials (RCT) involving adult patients with BBS comparing MPS to CSEMS in terms of stricture resolution, recurrence, technical success, number of required procedures and stents, treatment duration, all-cause mortality, adverse events, and stent migration. We utilized the Cochrane Risk of Bias (RoB) tool2 for study quality assessment. Meta-analysis following the random effects model was performed. After screening 365 references, we included 7 RCTs (high RoB) involving 594 patients. Most reported stricture etiology is chronic pancreatitis (52.4%), followed by orthotopic liver transplant (40.5%). Compared with MPS, CSEMS achieved similar efficacy and safety. However, CSEMS required fewer procedures (mean difference [MD]: −1.84 [−2.56 to −1.11]; I2 = 76%) and stents (MD: −6.04 [−9.55 to −2.52]; I2 = 93%), amounting for shorter duration of treatment (MD: −119.02 days [−137.41 to −100.62]; I2 = 96%) and savings in costs between 41 and 57% with absolute savings of 4,019$ to 9,192$ favoring CSEMS. All outcomes had a low to very low certainty of evidence (CoE), except for technical success and stricture resolution (moderate CoE). Our analysis suggests that CSEMSs are comparable to MPSs in terms of efficacy and safety. However, it shows that CSEMSs are more cost-effective. Sample size calculations from our analyses can guide the design of future studies to validate the safety profiles and determine the feasibility of the two modalities.

Institutions

Publication Details

Journal
Avicenna Journal of Medicine
Published
2026-03-24
DOI
https://doi.org/10.1055/s-0046-1818623
Primary Topic
Gallbladder and Bile Duct Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Covered Self-Expandable Metallic Stents versus Multiple Plastic Stents for Benign Biliary Strictures: A Systematic Review, Meta-Analysis, and Trial Sequential Analysis

Avicenna Journal of Medicine
Gallbladder and Bile Duct Disorders
article

Covered Self-Expandable Metallic Stents versus Multiple Plastic Stents for Benign Biliary Strictures: A Systematic Review, Meta-Analysis, and Trial Sequential Analysis

article en

Abstract

Abstract We aim to compare the benefits, harms, and costs of multiple plastic stents (MPS) versus covered self-expandable metallic stents (CSEMS) in the treatment of benign biliary strictures (BBS). A comprehensive database search through June 6, 2024 identified randomized controlled trials (RCT) involving adult patients with BBS comparing MPS to CSEMS in terms of stricture resolution, recurrence, technical success, number of required procedures and stents, treatment duration, all-cause mortality, adverse events, and stent migration. We utilized the Cochrane Risk of Bias (RoB) tool2 for study quality assessment. Meta-analysis following the random effects model was performed. After screening 365 references, we included 7 RCTs (high RoB) involving 594 patients. Most reported stricture etiology is chronic pancreatitis (52.4%), followed by orthotopic liver transplant (40.5%). Compared with MPS, CSEMS achieved similar efficacy and safety. However, CSEMS required fewer procedures (mean difference [MD]: −1.84 [−2.56 to −1.11]; I2 = 76%) and stents (MD: −6.04 [−9.55 to −2.52]; I2 = 93%), amounting for shorter duration of treatment (MD: −119.02 days [−137.41 to −100.62]; I2 = 96%) and savings in costs between 41 and 57% with absolute savings of 4,019$ to 9,192$ favoring CSEMS. All outcomes had a low to very low certainty of evidence (CoE), except for technical success and stricture resolution (moderate CoE). Our analysis suggests that CSEMSs are comparable to MPSs in terms of efficacy and safety. However, it shows that CSEMSs are more cost-effective. Sample size calculations from our analyses can guide the design of future studies to validate the safety profiles and determine the feasibility of the two modalities.

Avicenna Journal of Medicine
Lahey Hospital and Medical Center (US), MetroHealth (US), Mayo Clinic (US), Georgetown University (US), Aristotle University of Thessaloniki (GR), Thomas Jefferson University Hospital (US), University of California System (US), University of California San Diego (US), Saint Francis Hospital (US), St. Francis Hospital (US), Lahey Medical Center (US), Mayo Clinic in Arizona (US), Mayo Clinic in Florida (US), Indiana University School of Medicine, Indiana University – Purdue University Indianapolis (US), University of Missouri (US), MedStar Health (US)
Good health and well-being
Openalex Percentile: Top 11%
Gallbladder and Bile Duct Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.