Analysis of Ripple/Harmonic Coupling Characteristics of M <sup>3</sup> C Under Grid‐Side Asymmetric Faults

ABSTRACT The secure operation of the fractional frequency transmission system faces significant challenges during grid‐side asymmetric faults. This vulnerability stems from two critical technical barriers: the frequency disparity between interconnected grids obscures post‐fault interaction mechanisms, complicating system response analysis and the inherent complexity of modular multi‐ level matrix converter introduces substantial analytical difficulties in fault characteristic identification. This paper proposes a 2D phasor analytical framework that systematically decouples the interactive relationships within M 3 C. Through an iterative analytical approach, the investigation reveals the dynamic cross‐coupling mechanisms between ripples and harmonics under asymmetric faults, particularly addressing the nonlinear interactions between bridge‐arm current and submodule capacitor voltage. The proposed method realises the modelling of multi‐component under‐grid‐side asymmetric faults, precisely delineates the internal coupling modes and further reveals the fault transmission mechanism in the form of a generalised model introduced by fault participation factors. The effectiveness of the proposed method and the accuracy of the analysis are validated through case studies involving three fault scenarios in MATLAB/Simulink.

Institutions

Publication Details

Journal
IET Generation Transmission & Distribution
Published
2026-01-01
DOI
https://doi.org/10.1049/gtd2.70282
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Ripple/Harmonic Coupling Characteristics of M 3 C Under Grid‐Side Asymmetric Faults

IET Generation Transmission & Distribution
HVDC Systems and Fault Protection
article

Analysis of Ripple/Harmonic Coupling Characteristics of M 3 C Under Grid‐Side Asymmetric Faults

article en

Abstract

ABSTRACT The secure operation of the fractional frequency transmission system faces significant challenges during grid‐side asymmetric faults. This vulnerability stems from two critical technical barriers: the frequency disparity between interconnected grids obscures post‐fault interaction mechanisms, complicating system response analysis and the inherent complexity of modular multi‐ level matrix converter introduces substantial analytical difficulties in fault characteristic identification. This paper proposes a 2D phasor analytical framework that systematically decouples the interactive relationships within M 3 C. Through an iterative analytical approach, the investigation reveals the dynamic cross‐coupling mechanisms between ripples and harmonics under asymmetric faults, particularly addressing the nonlinear interactions between bridge‐arm current and submodule capacitor voltage. The proposed method realises the modelling of multi‐component under‐grid‐side asymmetric faults, precisely delineates the internal coupling modes and further reveals the fault transmission mechanism in the form of a generalised model introduced by fault participation factors. The effectiveness of the proposed method and the accuracy of the analysis are validated through case studies involving three fault scenarios in MATLAB/Simulink.

IET Generation Transmission & DistributionVol. 20(1)
Xi'an Jiaotong University (CN), South China University of Technology (CN)
Openalex Percentile: Top 10%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis of Ripple/Harmonic Coupling Characteristics of M <sup>3</sup> C Under Grid‐Side Asymmetric Faults · IET Generation Transmission & Distribution (2026) | TGRS Research Map | TGRS