Influence of build orientation and storage duration on the accuracy of fused deposition modeling-fabricated polyetheretherketone removable partial denture frameworks

This study investigated the effects of build orientation and water-storage duration on the dimensional accuracy of fused deposition modeling (FDM)-fabricated polyetheretherketone (PEEK) removable partial denture (RPD) frameworks. The specimen geometry was designed using computer-aided design (CAD) software to simulate a maxillary RPD framework and printed in three build orientations (0°, 45°, 90°; n=6). After annealing, specimens were immersed in 37°C water and scanned after 24 h, 1 week, 1 month, 2 months, 4 months, and 6 months. Trueness was calculated by superimposing scanned stereolithography (STL) data onto the CAD reference, and precision was assessed within each group. Storage duration significantly influenced trueness and precision, with clinically acceptable accuracy achieved after 24 h and maintained stable for more than 2 months under simulated intraoral moisture and temperature. The 90° orientation demonstrated the most consistent reproducibility.

Institutions

Publication Details

Journal
Dental Materials Journal
Published
2026-01-01
DOI
https://doi.org/10.4012/dmj.2025-280
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Influence of build orientation and storage duration on the accuracy of fused deposition modeling-fabricated polyetheretherketone removable partial denture frameworks

Dental Materials Journal
Dental materials and restorations
article

Influence of build orientation and storage duration on the accuracy of fused deposition modeling-fabricated polyetheretherketone removable partial denture frameworks

article en

Abstract

This study investigated the effects of build orientation and water-storage duration on the dimensional accuracy of fused deposition modeling (FDM)-fabricated polyetheretherketone (PEEK) removable partial denture (RPD) frameworks. The specimen geometry was designed using computer-aided design (CAD) software to simulate a maxillary RPD framework and printed in three build orientations (0°, 45°, 90°; n=6). After annealing, specimens were immersed in 37°C water and scanned after 24 h, 1 week, 1 month, 2 months, 4 months, and 6 months. Trueness was calculated by superimposing scanned stereolithography (STL) data onto the CAD reference, and precision was assessed within each group. Storage duration significantly influenced trueness and precision, with clinically acceptable accuracy achieved after 24 h and maintained stable for more than 2 months under simulated intraoral moisture and temperature. The 90° orientation demonstrated the most consistent reproducibility.

Dental Materials Journal
Tokyo Medical and Dental University (JP), University of Zurich (CH), Life Science Institute (JP)
Clean water and sanitation
Openalex Percentile: Top 10%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Influence of build orientation and storage duration on the accuracy of fused deposition modeling-fabricated polyetheretherketone removable partial denture frameworks · Dental Materials Journal (2026) | TGRS Research Map | TGRS