Advanced Biosensing Strategies for Last-Line Antibiotics Vancomycin, Colistin, Daptomycin and Meropenem: Comparative Analysis of Electrochemical and Optical Detection Methods

Background/Objectives: In the area of pharmacology and clinical research, it is necessary to use versatile technologies able to quantify last-line antibiotic molecules with high specificity and sensitivity. This article describes the development of two types of immunosensors based on amperometric and surface plasmon resonance (SPR) measurements and their applicability in the measurement/assessment of therapeutic drug monitoring (TDM) of four last-line antibiotics such as vancomycin, colistin, daptomycin and meropenem in human plasma. In this study, ligand immobilization by preconcentration assays, sensor surface regeneration, determination of sensitivity and correlation of plasma sample quantification results by HPLC were considered. Results: In the case of the electrochemical biosensor the IC50 values obtained were 3.49 μg/L for vancomycin (VAN), 5.44 μg/L for colistin (COL), 0.82 μg/L for meropenem (MER) and 5.10 μg/L for daptomycin (DAP). For the SPRi biosensor the LODs achieved were 19 ng/mL for VAN, 9 μg/L for COL, 12 μg/L for MER and 12.3 μg/L for DAP. Finally, both electrochemical biosensor and the SPRi optical biosensor showed that for the four antibiotics the standard deviations were less than 10% with respect to the HPLC results, with ranges for VAN between ~5–6 µg/mL, for COL ~0.2–0.7 µg/mL, for MER ~4.5–5.5 µg/mL and for DAP ~0.09–0.65 µg/mL. Conclusions: These kinds of biosensors provide a precise and sensitive strategy, together with real-time determination, to quantify last-line antibiotics, with working ranges like those shown by robust techniques such as HPLC and great potential for the clinic.

Institutions

Publication Details

Journal
Antibiotics
Published
2026-03-24
DOI
https://doi.org/10.3390/antibiotics15040327
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advanced Biosensing Strategies for Last-Line Antibiotics Vancomycin, Colistin, Daptomycin and Meropenem: Comparative Analysis of Electrochemical and Optical Detection Methods

Antibiotics
Advanced biosensing and bioanalysis techniques
article

Advanced Biosensing Strategies for Last-Line Antibiotics Vancomycin, Colistin, Daptomycin and Meropenem: Comparative Analysis of Electrochemical and Optical Detection Methods

article en

Abstract

Background/Objectives: In the area of pharmacology and clinical research, it is necessary to use versatile technologies able to quantify last-line antibiotic molecules with high specificity and sensitivity. This article describes the development of two types of immunosensors based on amperometric and surface plasmon resonance (SPR) measurements and their applicability in the measurement/assessment of therapeutic drug monitoring (TDM) of four last-line antibiotics such as vancomycin, colistin, daptomycin and meropenem in human plasma. In this study, ligand immobilization by preconcentration assays, sensor surface regeneration, determination of sensitivity and correlation of plasma sample quantification results by HPLC were considered. Results: In the case of the electrochemical biosensor the IC50 values obtained were 3.49 μg/L for vancomycin (VAN), 5.44 μg/L for colistin (COL), 0.82 μg/L for meropenem (MER) and 5.10 μg/L for daptomycin (DAP). For the SPRi biosensor the LODs achieved were 19 ng/mL for VAN, 9 μg/L for COL, 12 μg/L for MER and 12.3 μg/L for DAP. Finally, both electrochemical biosensor and the SPRi optical biosensor showed that for the four antibiotics the standard deviations were less than 10% with respect to the HPLC results, with ranges for VAN between ~5–6 µg/mL, for COL ~0.2–0.7 µg/mL, for MER ~4.5–5.5 µg/mL and for DAP ~0.09–0.65 µg/mL. Conclusions: These kinds of biosensors provide a precise and sensitive strategy, together with real-time determination, to quantify last-line antibiotics, with working ranges like those shown by robust techniques such as HPLC and great potential for the clinic.

AntibioticsVol. 15(4)
Universidad de La Sabana (CO), Biomedical Research Networking Center in Bioengineering, Biomaterials and Nanomedicine (ES), Institute of Advanced Chemistry of Catalonia (ES)
Openalex Percentile: Top 11%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Advanced Biosensing Strategies for Last-Line Antibiotics Vancomycin, Colistin, Daptomycin and Meropenem: Comparative Analysis of Electrochemical and Optical Detection Methods · Antibiotics (2026) | TGRS Research Map | TGRS