Novel Implementation of a Microvascular Coupler Device in Kidney Transplantation: Case Report

The demand for kidney transplantation remains unmet, highlighting the need to maximize the pool of potential donors. Up to one‐third of the population has accessory renal arteries, which can present challenges when used in donor grafts while maintaining adequate perfusion to the entire kidney. Various reconstruction options are technically demanding and can increase the warm ischemic time of the graft. The microvascular coupler device (MACD), commonly used in free flaps, was designed to facilitate the anastomosis of small vessels. We present the first documented successful use of the MACD in kidney transplantation, used for the anastomosis of a small accessory renal artery (ARA) to the recipient’s inferior epigastric artery.

Authors

Institutions

Publication Details

Journal
Case Reports in Transplantation
Published
2026-01-01
DOI
https://doi.org/10.1155/crit/5988191
Primary Topic
Renal and Vascular Pathologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Implementation of a Microvascular Coupler Device in Kidney Transplantation: Case Report

Michael Au, Joseph Moryousef, Aisling Zeng, Rahul Bansal et al.
Case Reports in Transplantation
Renal and Vascular Pathologies
article

Novel Implementation of a Microvascular Coupler Device in Kidney Transplantation: Case Report

Michael Au, Joseph Moryousef, Aisling Zeng, Rahul Bansal, Shahid Lambe, Yanbo Guo, Patricia Procner
article en

Abstract

The demand for kidney transplantation remains unmet, highlighting the need to maximize the pool of potential donors. Up to one‐third of the population has accessory renal arteries, which can present challenges when used in donor grafts while maintaining adequate perfusion to the entire kidney. Various reconstruction options are technically demanding and can increase the warm ischemic time of the graft. The microvascular coupler device (MACD), commonly used in free flaps, was designed to facilitate the anastomosis of small vessels. We present the first documented successful use of the MACD in kidney transplantation, used for the anastomosis of a small accessory renal artery (ARA) to the recipient’s inferior epigastric artery.

Case Reports in TransplantationVol. 2026(1)
St. Joseph’s Healthcare Hamilton (CA), McMaster University (CA)
Good health and well-being
Openalex Percentile: Top 12%
Renal and Vascular Pathologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.