Reverse-phase High-performance Liquid Chromatography: High-performance Liquid Chromatography Method Used for Estimating Cefuroxime Axetil in Tablet and Bulk Dosage Formulations

A BSTRACT Background: Cefuroxime axetil, an effective second-generation cephalosporin antibiotic, requires valid analytical technique for bulk medication and tablet quality control. Aim and Objective: The current study developed a speedy, efficient, accurate, and cost-effective RP-HPLC (Reverse Phase High Performance Liquid Chromatography) technology that has been developed and validated for the quantification of Cefuroxime axetil in bulk and pharmaceutical formulations using a C8 column. Materials and Methods: The chromatography method employed a Base Deactivated Silica(BDS)-Hyperil C8 column (250 × 4.6 mm, 5 microns) with a mobile phase of acetonitrile and water at a 55:45 v/v ratio, at a flow rate of 1.025 ml/min. The method supports green principles was analyzed using a Shimadzu-LC-20AT HPLC system at a wavelength of 277 nm. The approach was assessed in accordance with ICH(International Council for Harmonisation) criteria. Results and Discussion: The results indicated the trustworthiness of the marketed formulation (cefakind 500 mg), with a purity of 99.09%. The retention time of Cefuroxime Axetil was 4.349 ± 0.02 minutes, with a correlation value ( R ²) of 0.9998, demonstrating excellent linearity within the 30-70 µg/mL range. The limits of detection (LOD) and quantification (LOQ) were 0.0180 µg/ml and 0.0546 µg/ml, respectively. The average recovery was 99.09%, guaranteeing exceptional precision. The approach demonstrated accuracy (% RSD = 0.06) and robustness against minor fluctuations in analytical conditions. The suggested RP-HPLC method is straightforward, swift, precise, accurate, and cost-effective, rendering it appropriate for regular quality control, dissolution analysis, and bioequivalence assessment of Cefuroxime axetil in pharmaceutical formulations.

Authors

Institutions

Publication Details

Journal
Asian Journal of Pharmaceutical Research and Health Care
Published
2026-01-01
DOI
https://doi.org/10.4103/ajprhc.ajprhc_92_25
Primary Topic
Antibiotics Pharmacokinetics and Efficacy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reverse-phase High-performance Liquid Chromatography: High-performance Liquid Chromatography Method Used for Estimating Cefuroxime Axetil in Tablet and Bulk Dosage Formulations

Penta Dolly Chaitanya Sudha, K. N. V. Chenchu Lakshmi, Brian Emmanuel Mremi, K. Ravishankar et al.
Asian Journal of Pharmaceutical Research and Health Care
Antibiotics Pharmacokinetics and Efficacy
article

Reverse-phase High-performance Liquid Chromatography: High-performance Liquid Chromatography Method Used for Estimating Cefuroxime Axetil in Tablet and Bulk Dosage Formulations

Penta Dolly Chaitanya Sudha, K. N. V. Chenchu Lakshmi, Brian Emmanuel Mremi, K. Ravishankar, Chinnam Naidu Botta, Shaik Reehana
article en

Abstract

A BSTRACT Background: Cefuroxime axetil, an effective second-generation cephalosporin antibiotic, requires valid analytical technique for bulk medication and tablet quality control. Aim and Objective: The current study developed a speedy, efficient, accurate, and cost-effective RP-HPLC (Reverse Phase High Performance Liquid Chromatography) technology that has been developed and validated for the quantification of Cefuroxime axetil in bulk and pharmaceutical formulations using a C8 column. Materials and Methods: The chromatography method employed a Base Deactivated Silica(BDS)-Hyperil C8 column (250 × 4.6 mm, 5 microns) with a mobile phase of acetonitrile and water at a 55:45 v/v ratio, at a flow rate of 1.025 ml/min. The method supports green principles was analyzed using a Shimadzu-LC-20AT HPLC system at a wavelength of 277 nm. The approach was assessed in accordance with ICH(International Council for Harmonisation) criteria. Results and Discussion: The results indicated the trustworthiness of the marketed formulation (cefakind 500 mg), with a purity of 99.09%. The retention time of Cefuroxime Axetil was 4.349 ± 0.02 minutes, with a correlation value ( R ²) of 0.9998, demonstrating excellent linearity within the 30-70 µg/mL range. The limits of detection (LOD) and quantification (LOQ) were 0.0180 µg/ml and 0.0546 µg/ml, respectively. The average recovery was 99.09%, guaranteeing exceptional precision. The approach demonstrated accuracy (% RSD = 0.06) and robustness against minor fluctuations in analytical conditions. The suggested RP-HPLC method is straightforward, swift, precise, accurate, and cost-effective, rendering it appropriate for regular quality control, dissolution analysis, and bioequivalence assessment of Cefuroxime axetil in pharmaceutical formulations.

Asian Journal of Pharmaceutical Research and Health CareVol. 18(1)
Siddhartha Medical College (IN), Aurobindo Pharma (India) (IN), Koneru Lakshmaiah Education Foundation (IN)
Openalex Percentile: Top 11%
Antibiotics Pharmacokinetics and Efficacy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.