A VSG Transient Improvement Method from the Perspective of Equivalent Circuits

Virtual Synchronous Generator (VSG) has become a prominent candidate to control grid-tied power electronic inverters for its ability to provide inertial support and improve power system frequency stability. However, under disturbances, VSG exhibits significant oscillations in its output frequency and power. Meanwhile, existing oscillation suppression methods rely on somewhat complex modeling and cumbersome parameter tuning. To address this issue, this paper proposes a straightforward approach to improving the transient performance of VSG based on the equivalent circuit model of the VSG active power loop. First, it is shown that the parameters in the VSG active power loop have a one-to-one correspondence with the elements of a RLC circuit. Based on the equivalent circuit model of VSG control, it is demonstrated that under the constraints of ROCOF and power–frequency droop limitation, oscillation suppression cannot be effectively achieved only by parameter tuning. Thus, an additional damping resistance branch is introduced into the VSG equivalent circuit model. The quantitative parameter design method of this damping branch is further introduced. Finally, high-power experiments demonstrate that the proposed method effectively suppresses power oscillations and enhances the transient performance of VSGs.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-03-23
DOI
https://doi.org/10.3390/en19061575
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A VSG Transient Improvement Method from the Perspective of Equivalent Circuits

Yi Tan, X. T. Huang, Haili LIU, Mai Pan et al.
Energies
Microgrid Control and Optimization
article

A VSG Transient Improvement Method from the Perspective of Equivalent Circuits

Yi Tan, X. T. Huang, Haili LIU, Mai Pan, Yipeng Liu, Hao Bai
article en

Abstract

Virtual Synchronous Generator (VSG) has become a prominent candidate to control grid-tied power electronic inverters for its ability to provide inertial support and improve power system frequency stability. However, under disturbances, VSG exhibits significant oscillations in its output frequency and power. Meanwhile, existing oscillation suppression methods rely on somewhat complex modeling and cumbersome parameter tuning. To address this issue, this paper proposes a straightforward approach to improving the transient performance of VSG based on the equivalent circuit model of the VSG active power loop. First, it is shown that the parameters in the VSG active power loop have a one-to-one correspondence with the elements of a RLC circuit. Based on the equivalent circuit model of VSG control, it is demonstrated that under the constraints of ROCOF and power–frequency droop limitation, oscillation suppression cannot be effectively achieved only by parameter tuning. Thus, an additional damping resistance branch is introduced into the VSG equivalent circuit model. The quantitative parameter design method of this damping branch is further introduced. Finally, high-power experiments demonstrate that the proposed method effectively suppresses power oscillations and enhances the transient performance of VSGs.

EnergiesVol. 19(6)
China Southern Power Grid (China) (CN)
Affordable and clean energy
Openalex Percentile: Top 10%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.