The Choice of the Control in the Single-Phase Voltage Source Inverters for UPS Systems

The paper presents four solutions to the voltage source inverter (VSI) control system with existing delays in the measurement channels and the middle switching frequency (25,600 Hz): Single-Input Single-Output Coefficient Diagram Method (SISO-CDM), Multi-Input Multi-Output Passivity-Based Control (MISO-PBC), Multi-Input Multi-Output One-Sample-Ahead Preview Controller (MISO-OSAP), and MISO-OSAP with Luenberger Observer (MISO-OSAP-LO). The theory, including adjustments to controller gains or to the coefficients of the characteristic equation of the closed-loop system, is presented. Simulations of the VSI operation with these control systems for the nonlinear load and the dynamic resistive load (per the requirements of the EN 62040-3 standard) are presented. The SISO-CDM and MISO-PBC are finally selected for experimental verification of the simulations. The results of the tests enable the selection of the control type for a particular VSI design based on its cost and an estimation of the advantages of the more expensive solution. The paper should help in engineering design according to the remarks in the paper.

Authors

Institutions

Publication Details

Journal
Energies
Published
2026-03-20
DOI
https://doi.org/10.3390/en19061548
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Choice of the Control in the Single-Phase Voltage Source Inverters for UPS Systems

Zbigniew Rymarski
Energies
Microgrid Control and Optimization
article

The Choice of the Control in the Single-Phase Voltage Source Inverters for UPS Systems

Zbigniew Rymarski
article en

Abstract

The paper presents four solutions to the voltage source inverter (VSI) control system with existing delays in the measurement channels and the middle switching frequency (25,600 Hz): Single-Input Single-Output Coefficient Diagram Method (SISO-CDM), Multi-Input Multi-Output Passivity-Based Control (MISO-PBC), Multi-Input Multi-Output One-Sample-Ahead Preview Controller (MISO-OSAP), and MISO-OSAP with Luenberger Observer (MISO-OSAP-LO). The theory, including adjustments to controller gains or to the coefficients of the characteristic equation of the closed-loop system, is presented. Simulations of the VSI operation with these control systems for the nonlinear load and the dynamic resistive load (per the requirements of the EN 62040-3 standard) are presented. The SISO-CDM and MISO-PBC are finally selected for experimental verification of the simulations. The results of the tests enable the selection of the control type for a particular VSI design based on its cost and an estimation of the advantages of the more expensive solution. The paper should help in engineering design according to the remarks in the paper.

EnergiesVol. 19(6)
Silesian University of Technology (PL)
Openalex Percentile: Top 10%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.