Bioinductive Collagen Augmentation in Arthroscopic Rotator Cuff Repair: 24-Month MRI and Clinical Outcomes

<b>Background/Objectives:</b> Rotator cuff repair (RCR) is a common orthopedic procedure, with healing outcomes strongly influenced by patient-specific factors such as tissue quality, tear characteristics, and biological healing potential. Bioinductive collagen implants have shown great results in enhancing tendon healing and reducing retear rate. This study aimed to evaluate the clinical and imaging outcomes of RCR augmented with a xeno-derived collagen membrane over 24 months and to assess complications or implant failures. <b>Methods:</b> Patients underwent arthroscopic RCR using anchors (single or double-row) with additional xeno-derived matrix augmentation. The study included patients older than 40 years with full-thickness supraspinatus and/or infraspinatus tendon tears (DeOrio-Cofield grade 3-4) who were candidates for arthroscopic rotator cuff repair and provided informed consent. Clinical outcomes were assessed using the Constant-Murley Score (CMS), Disabilities of the Arm, Shoulder and Hand score (DASH), and Visual Analogue Score (VAS) at baseline, 3, 6, 12, and 24 months. MRI was performed preoperatively and at 24 months to assess tendon thickness. <b>Results:</b> All scores improved significantly. CMS increased from 16.3 ± 4.1 to 82.9 ± 5.8, VAS decreased from 7.8 ± 1.0 to 1.5 ± 0.8, and DASH improved from 70.3 ± 6.4 to 12.4 ± 4.5 (<i>p</i> < 0.05). Tendon thickness in the supraspinatus (T3) increased from 4.2 ± 0.9 mm to 6.8 ± 1.2 mm (<i>p</i> < 0.05). Retear rate was 7.55%, with no major complications. <b>Conclusions:</b> The bioinductive collagen implant showed notable results in improving tendon thickness, healing, and excellent clinical outcomes in RCR, without membrane-related complications. The study was designed as a prospective single-arm case series without a control group and that was the main limitation; The absence of adverse reactions in this cohort further supports the favorable safety profile of this implant in the present study population.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-03-22
DOI
https://doi.org/10.3390/jcm15062435
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bioinductive Collagen Augmentation in Arthroscopic Rotator Cuff Repair: 24-Month MRI and Clinical Outcomes

D. De Amicis, Francesco Calafiore, Francesco Raffelini, Riccardo Fabiani et al.
Journal of Clinical Medicine
Shoulder Injury and Treatment
article

Bioinductive Collagen Augmentation in Arthroscopic Rotator Cuff Repair: 24-Month MRI and Clinical Outcomes

D. De Amicis, Francesco Calafiore, Francesco Raffelini, Riccardo Fabiani, Andrea Fidanza, Luca Andriollo, Aurelio Picchi, Giandomenico Logroscino, Michela Saracco
article en

Abstract

<b>Background/Objectives:</b> Rotator cuff repair (RCR) is a common orthopedic procedure, with healing outcomes strongly influenced by patient-specific factors such as tissue quality, tear characteristics, and biological healing potential. Bioinductive collagen implants have shown great results in enhancing tendon healing and reducing retear rate. This study aimed to evaluate the clinical and imaging outcomes of RCR augmented with a xeno-derived collagen membrane over 24 months and to assess complications or implant failures. <b>Methods:</b> Patients underwent arthroscopic RCR using anchors (single or double-row) with additional xeno-derived matrix augmentation. The study included patients older than 40 years with full-thickness supraspinatus and/or infraspinatus tendon tears (DeOrio-Cofield grade 3-4) who were candidates for arthroscopic rotator cuff repair and provided informed consent. Clinical outcomes were assessed using the Constant-Murley Score (CMS), Disabilities of the Arm, Shoulder and Hand score (DASH), and Visual Analogue Score (VAS) at baseline, 3, 6, 12, and 24 months. MRI was performed preoperatively and at 24 months to assess tendon thickness. <b>Results:</b> All scores improved significantly. CMS increased from 16.3 ± 4.1 to 82.9 ± 5.8, VAS decreased from 7.8 ± 1.0 to 1.5 ± 0.8, and DASH improved from 70.3 ± 6.4 to 12.4 ± 4.5 (<i>p</i> < 0.05). Tendon thickness in the supraspinatus (T3) increased from 4.2 ± 0.9 mm to 6.8 ± 1.2 mm (<i>p</i> < 0.05). Retear rate was 7.55%, with no major complications. <b>Conclusions:</b> The bioinductive collagen implant showed notable results in improving tendon thickness, healing, and excellent clinical outcomes in RCR, without membrane-related complications. The study was designed as a prospective single-arm case series without a control group and that was the main limitation; The absence of adverse reactions in this cohort further supports the favorable safety profile of this implant in the present study population.

Journal of Clinical MedicineVol. 15(6)
University of Teramo (IT), University of L'Aquila (IT), Federico II University Hospital (IT), Fondazione Poliambulanza Istituto Ospedaliero (IT), University of Naples Federico II (IT)
Good health and well-being
Openalex Percentile: Top 12%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.