Sectoral Analysis of Corneal Thickness in Glaucoma and Healthy Eyes and Its Relationship with RNFL and Rim Area

<b>Background/Objectives</b>: To characterize sectoral corneal thickness (CT) profiles in eyes with primary open-angle glaucoma (POAG) compared with healthy eyes and to evaluate potential associations between CT, retinal nerve fiber layer (RNFL) thickness, and optic disc rim area (RA). <b>Methods</b>: In this cross-sectional study, 192 participants (91 with POAG and 101 controls) contributed 297 eyes (145 glaucoma eyes and 152 control eyes). All participants underwent comprehensive ophthalmological examination and spectral-domain optical coherence tomography (OCT; Optovue Solix, Fremont, CA, USA) to obtain peripapillary RNFL measurements, optic disc rim area, and corneal pachymetry maps across five sectors (central, superior, inferior, temporal, and nasal). Repeated-measures correlation analyses were used to assess within-subject associations between CT and RA, and generalized estimating equation (GEE) models were applied to evaluate independent associations between CT, glaucoma status, disease severity, and RNFL thickness while adjusting for relevant covariates. <b>Results</b>: Eyes with POAG exhibited significantly thinner corneas across all sectors compared with controls (all <i>p</i> < 0.05), with the greatest differences observed in the superior (median 607.0 μm vs. 640.0 μm, <i>p</i> < 0.001) and temporal (562.0 μm vs. 579.5 μm, <i>p</i> < 0.001) regions. Average RNFL thickness and rim area were also significantly reduced in glaucoma eyes (all <i>p</i> < 0.001). However, no independent associations between sectoral CT and RNFL thickness or RA were observed after adjustment for multiple comparisons. Although nominal associations between thinner inferotemporal CT and reduced RNFL thickness were observed in unadjusted analyses, these did not remain statistically significant after false discovery rate correction. In multivariable GEE models, glaucoma diagnosis and greater disease severity were consistently associated with reduced RNFL thickness (β range: -11.0 to -42.2 μm; all <i>p</i> < 0.001), whereas CT was not independently associated with RNFL thickness (all adjusted <i>p</i> > 0.07). <b>Conclusions</b>: Sectoral corneal thickness is significantly reduced in eyes with POAG but does not independently correlate with RNFL thickness or optic disc rim area after adjustment for confounding factors. These findings support the concept that corneal thinning reflects structural and biomechanical susceptibility to glaucoma rather than serving as a marker of established neuroretinal damage severity. Further longitudinal studies incorporating comprehensive biomechanical assessments are warranted to clarify the role of corneal structure in glaucoma pathophysiology.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-03-21
DOI
https://doi.org/10.3390/jcm15062405
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Sectoral Analysis of Corneal Thickness in Glaucoma and Healthy Eyes and Its Relationship with RNFL and Rim Area

Anita Lyssek-Boroń, Beniamin Oskar Grabarek, Piotr Miklaszewski, Katarzyna Krysik et al.
Journal of Clinical Medicine
Glaucoma and retinal disorders
article

Sectoral Analysis of Corneal Thickness in Glaucoma and Healthy Eyes and Its Relationship with RNFL and Rim Area

Anita Lyssek-Boroń, Beniamin Oskar Grabarek, Piotr Miklaszewski, Katarzyna Krysik, Dominika Janiszewska-Bil, Dariusz Dobrowolski, Zuzanna Lelek, Anna Maria Gadamer, Michael Janusz Koss, Edward Wylęgała
article en

Abstract

<b>Background/Objectives</b>: To characterize sectoral corneal thickness (CT) profiles in eyes with primary open-angle glaucoma (POAG) compared with healthy eyes and to evaluate potential associations between CT, retinal nerve fiber layer (RNFL) thickness, and optic disc rim area (RA). <b>Methods</b>: In this cross-sectional study, 192 participants (91 with POAG and 101 controls) contributed 297 eyes (145 glaucoma eyes and 152 control eyes). All participants underwent comprehensive ophthalmological examination and spectral-domain optical coherence tomography (OCT; Optovue Solix, Fremont, CA, USA) to obtain peripapillary RNFL measurements, optic disc rim area, and corneal pachymetry maps across five sectors (central, superior, inferior, temporal, and nasal). Repeated-measures correlation analyses were used to assess within-subject associations between CT and RA, and generalized estimating equation (GEE) models were applied to evaluate independent associations between CT, glaucoma status, disease severity, and RNFL thickness while adjusting for relevant covariates. <b>Results</b>: Eyes with POAG exhibited significantly thinner corneas across all sectors compared with controls (all <i>p</i> < 0.05), with the greatest differences observed in the superior (median 607.0 μm vs. 640.0 μm, <i>p</i> < 0.001) and temporal (562.0 μm vs. 579.5 μm, <i>p</i> < 0.001) regions. Average RNFL thickness and rim area were also significantly reduced in glaucoma eyes (all <i>p</i> < 0.001). However, no independent associations between sectoral CT and RNFL thickness or RA were observed after adjustment for multiple comparisons. Although nominal associations between thinner inferotemporal CT and reduced RNFL thickness were observed in unadjusted analyses, these did not remain statistically significant after false discovery rate correction. In multivariable GEE models, glaucoma diagnosis and greater disease severity were consistently associated with reduced RNFL thickness (β range: -11.0 to -42.2 μm; all <i>p</i> < 0.001), whereas CT was not independently associated with RNFL thickness (all adjusted <i>p</i> > 0.07). <b>Conclusions</b>: Sectoral corneal thickness is significantly reduced in eyes with POAG but does not independently correlate with RNFL thickness or optic disc rim area after adjustment for confounding factors. These findings support the concept that corneal thinning reflects structural and biomechanical susceptibility to glaucoma rather than serving as a marker of established neuroretinal damage severity. Further longitudinal studies incorporating comprehensive biomechanical assessments are warranted to clarify the role of corneal structure in glaucoma pathophysiology.

Journal of Clinical MedicineVol. 15(6)
Instytut Kolejnictwa (PL), Medical University of Silesia (PL), Heidelberg University (DE), Augenklinik Heidelberg (DE), Blindeninstitutsstiftung (DE), Academy of Fine Arts in Katowice (PL), WSB University (PL)
Openalex Percentile: Top 11%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.