A hollow-core fiber based optofluidic chip for rapid immunofluorescence detection with simultaneous enhancement of sensitivity and enrichment efficiency

Although conventional ELISA is highly sensitive, its intricate workflow, significant background interference and dependence on laboratory infrastructure severely restrict its use for on-site testing. Lateral-flow assays (LFAs) are simple and portable, yet the numerous manual steps and inability to deliver truly quantitative results lead to inadequate sensitivity and poor reliability, failing to meet clinical requirements. Therefore, there is an urgent need for an immunological method that is both highly sensitive and simple to perform. Here, we propose an all-fiber optofluidic immunosensor based on a hollow-core fiber (HCF) that integrates the entire assay onto a single microfluidic chip. A standard fiber is inserted into the HCF for direct light coupling, and the gap between the two fibers serves as the sample inlet, eliminating external pumps and tubing. The inner wall of the HCF can be functionalized, providing an extremely high surface-to-volume ratio; the long, confined microchannel shortens analyte diffusion distances and prolongs residence time, markedly improving antibody-capture efficiency and reducing enrichment duration. Coaxial propagation of both light and the sample inside the HCF strengthens light-matter interaction and enhances fluorescence collection efficiency. Without any pre-incubation, quantitative detection of influenza A antigen is completed within 10 min, achieving a limit of detection of 2.41 pg mL<sup>-1</sup>. The limit of detection and assay time of this method are both lower than those of many conventional lateral flow immunoassay cases, and the method exhibits excellent reproducibility and specificity. The proposed HCF microfluidic chip successfully breaks the conventional sensitivity-<i>versus</i>-speed trade-off, offering a promising solution for rapid point-of-care clinical diagnostics.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2026-01-01
DOI
https://doi.org/10.1039/d5an01308a
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A hollow-core fiber based optofluidic chip for rapid immunofluorescence detection with simultaneous enhancement of sensitivity and enrichment efficiency

Yanqing Lu, Feng Lin, Guanghui Wang, Lunbiao Cui et al.
The Analyst
Biosensors and Analytical Detection
article

A hollow-core fiber based optofluidic chip for rapid immunofluorescence detection with simultaneous enhancement of sensitivity and enrichment efficiency

Yanqing Lu, Feng Lin, Guanghui Wang, Lunbiao Cui, Zhenyong Dong, Xiao Ming Ren, Yukai Liu, Xiaoxian Liu, Hao Wang, Tian Wen
article en

Abstract

Although conventional ELISA is highly sensitive, its intricate workflow, significant background interference and dependence on laboratory infrastructure severely restrict its use for on-site testing. Lateral-flow assays (LFAs) are simple and portable, yet the numerous manual steps and inability to deliver truly quantitative results lead to inadequate sensitivity and poor reliability, failing to meet clinical requirements. Therefore, there is an urgent need for an immunological method that is both highly sensitive and simple to perform. Here, we propose an all-fiber optofluidic immunosensor based on a hollow-core fiber (HCF) that integrates the entire assay onto a single microfluidic chip. A standard fiber is inserted into the HCF for direct light coupling, and the gap between the two fibers serves as the sample inlet, eliminating external pumps and tubing. The inner wall of the HCF can be functionalized, providing an extremely high surface-to-volume ratio; the long, confined microchannel shortens analyte diffusion distances and prolongs residence time, markedly improving antibody-capture efficiency and reducing enrichment duration. Coaxial propagation of both light and the sample inside the HCF strengthens light-matter interaction and enhances fluorescence collection efficiency. Without any pre-incubation, quantitative detection of influenza A antigen is completed within 10 min, achieving a limit of detection of 2.41 pg mL<sup>-1</sup>. The limit of detection and assay time of this method are both lower than those of many conventional lateral flow immunoassay cases, and the method exhibits excellent reproducibility and specificity. The proposed HCF microfluidic chip successfully breaks the conventional sensitivity-<i>versus</i>-speed trade-off, offering a promising solution for rapid point-of-care clinical diagnostics.

The Analyst
Anhui Agricultural University (CN), Jiangsu Provincial Center for Disease Control and Prevention (CN), Nanjing University (CN)
Industry, innovation and infrastructure
Openalex Percentile: Top 12%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.