Mammal, reptile, amphibian and invertebrate electrocutions on electric power networks in Iran

Abstract Electrical power systems are a ubiquitous part of the Anthropocene. Wildlife interactions with these systems can be positive, for example when natural nesting substrates are limited, but are frequently negative, for example when nests catch fire or nesting individuals are electrocuted. Electrocution research focuses primarily on birds because they, especially large species, are particularly prone to electrocution. However, many other animals are also electrocuted. To explore non-avian electrocutions, we used crowdsourced data from Iran, where electric utility personnel frequently describe unusual incidents on electric industry-focused social media channels. In posts from January 2014 to December 2023, we identified 120 reports of non-avian electrocutions involving mammals (74%), reptiles (24%), amphibians (1%) and invertebrates (< 1%). Most (91%) incidents involved correctly operating electrical systems, indicating that the design of these electrical systems did not account for potential animal contacts. A few (9%) involved malfunctioning electrical components (overturned or energized power poles) that would also have been hazardous to humans. The greatest number of electrocutions occurred as a result of contact with low-voltage and ground-mounted equipment. For example, 220–600 V freestanding switchboards accounted for about one-third of electrocutions. Many of the documented incidents involved outages (n = 71), or outages together with fire ignitions (n = 8), indicating cascading effects on human populations and the environment. Mitigation measures to prevent these incidents are widely available, and should be used throughout the electrical system. Future research should document and quantify non-avian incidents beyond Iran, to better understand the impact of electrical systems on non-avian wildlife.

Authors

Institutions

Publication Details

Journal
Oryx
Published
2026-03-23
DOI
https://doi.org/10.1017/s0030605324001613
Primary Topic
Wildlife-Road Interactions and Conservation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mammal, reptile, amphibian and invertebrate electrocutions on electric power networks in Iran

Francisco S. Tortosa, Mahmood Kolnegari, José Guerrero-Casado, James F. Dwyer
Oryx
Wildlife-Road Interactions and Conservation
article

Mammal, reptile, amphibian and invertebrate electrocutions on electric power networks in Iran

Francisco S. Tortosa, Mahmood Kolnegari, José Guerrero-Casado, James F. Dwyer
article en

Abstract

Abstract Electrical power systems are a ubiquitous part of the Anthropocene. Wildlife interactions with these systems can be positive, for example when natural nesting substrates are limited, but are frequently negative, for example when nests catch fire or nesting individuals are electrocuted. Electrocution research focuses primarily on birds because they, especially large species, are particularly prone to electrocution. However, many other animals are also electrocuted. To explore non-avian electrocutions, we used crowdsourced data from Iran, where electric utility personnel frequently describe unusual incidents on electric industry-focused social media channels. In posts from January 2014 to December 2023, we identified 120 reports of non-avian electrocutions involving mammals (74%), reptiles (24%), amphibians (1%) and invertebrates (< 1%). Most (91%) incidents involved correctly operating electrical systems, indicating that the design of these electrical systems did not account for potential animal contacts. A few (9%) involved malfunctioning electrical components (overturned or energized power poles) that would also have been hazardous to humans. The greatest number of electrocutions occurred as a result of contact with low-voltage and ground-mounted equipment. For example, 220–600 V freestanding switchboards accounted for about one-third of electrocutions. Many of the documented incidents involved outages (n = 71), or outages together with fire ignitions (n = 8), indicating cascading effects on human populations and the environment. Mitigation measures to prevent these incidents are widely available, and should be used throughout the electrical system. Future research should document and quantify non-avian incidents beyond Iran, to better understand the impact of electrical systems on non-avian wildlife.

Oryx
Engineering Data Management (US)
Openalex Percentile: Top 15%
Wildlife-Road Interactions and Conservation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.