Purpose To compare the dosimetric characteristics of non-coplanar volumetric modulated arc therapy (VMAT) and TomoTherapy for hippocampal-avoidance prophylactic cranial irradiation (HA-PCI) in small cell lung cancer (SCLC) patients. Methods Ten SCLC patients who received HA-PCI were retrospectively analyzed. Two plans were generated as TrueBeam non-coplanar VMAT with four arcs and helical TomoTherapy. The hippocampal avoidance zone used a 3-mm margin, reduced from RTOG 0933’s 5-mm specification. Planning target volume of whole brain (PTV_WB) was prescribed 25 Gy in 10 fractions, normalized to D 95% =2500 cGy. RTOG 0933 hippocampal constraints (D max ≤ 1600 cGy, D 100% ≤900 cGy) were applied. Dosimetric parameters for hippocampus, PTV_WB, organs at risk, treatment efficiency (monitor units, delivery time), Paddick conformity index, and homogeneity index were compared using Wilcoxon signed-rank test. Results Non-coplanar VMAT achieved significantly lower hippocampal D max than TomoTherapy (1353 cGy vs 1638 cGy, p=0.004), meeting RTOG 0933 constraints, while TomoTherapy exceeded the per-protocol constraint by 38 cGy but remained within the acceptable deviation threshold, indicating clinically acceptable dosimetric outcomes. Non-coplanar VMAT demonstrated superior PTV_WB coverage: V 98% (96.68% vs 95.77%), V 95% (97.66% vs 96.48%), D 98% (2320 cGy vs 2095 cGy) (all p=0.004). Paddick conformity index was higher (0.91 vs 0.84, p=0.012) and homogeneity index lower (0.20 vs 0.27, p=0.004). Non-coplanar VMAT reduced monitor units by 88.5% (748 vs 6528 MU, p=0.004) and treatment time by 25.2% (287 vs 384 seconds, p=0.004). Bilateral eye D max was 21-27% lower (all p=0.004) and bilateral cochlear D max approximately 15% lower (p ≤ 0.008). Conclusions Non-coplanar VMAT demonstrated superior dosimetric characteristics compared to TomoTherapy for HA-PCI with 3-mm margin, meeting hippocampal constraints while improving target coverage and treatment efficiency. Prospective validation with neurocognitive outcomes is needed.

Authors

Institutions

Publication Details

Journal
Frontiers in Oncology
Published
2026-03-23
DOI
https://doi.org/10.3389/fonc.2026.1790929
Primary Topic
Brain Metastases and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric comparison of TomoTherapy and non-coplanar VMAT for hippocampal-avoidance prophylactic cranial irradiation

Yunji Seol, Ji Hyun Hong, Chan-Beom Park, Y. H. Lee et al.
Frontiers in Oncology
Brain Metastases and Treatment
article

Dosimetric comparison of TomoTherapy and non-coplanar VMAT for hippocampal-avoidance prophylactic cranial irradiation

Yunji Seol, Ji Hyun Hong, Chan-Beom Park, Y. H. Lee, J. Song, Young Nam Kang, Geum Seong Cheon, Yeon-Sil Kim, Kyu Hye Choi, Wonjoong Cheon
article en

Abstract

Purpose To compare the dosimetric characteristics of non-coplanar volumetric modulated arc therapy (VMAT) and TomoTherapy for hippocampal-avoidance prophylactic cranial irradiation (HA-PCI) in small cell lung cancer (SCLC) patients. Methods Ten SCLC patients who received HA-PCI were retrospectively analyzed. Two plans were generated as TrueBeam non-coplanar VMAT with four arcs and helical TomoTherapy. The hippocampal avoidance zone used a 3-mm margin, reduced from RTOG 0933’s 5-mm specification. Planning target volume of whole brain (PTV_WB) was prescribed 25 Gy in 10 fractions, normalized to D 95% =2500 cGy. RTOG 0933 hippocampal constraints (D max ≤ 1600 cGy, D 100% ≤900 cGy) were applied. Dosimetric parameters for hippocampus, PTV_WB, organs at risk, treatment efficiency (monitor units, delivery time), Paddick conformity index, and homogeneity index were compared using Wilcoxon signed-rank test. Results Non-coplanar VMAT achieved significantly lower hippocampal D max than TomoTherapy (1353 cGy vs 1638 cGy, p=0.004), meeting RTOG 0933 constraints, while TomoTherapy exceeded the per-protocol constraint by 38 cGy but remained within the acceptable deviation threshold, indicating clinically acceptable dosimetric outcomes. Non-coplanar VMAT demonstrated superior PTV_WB coverage: V 98% (96.68% vs 95.77%), V 95% (97.66% vs 96.48%), D 98% (2320 cGy vs 2095 cGy) (all p=0.004). Paddick conformity index was higher (0.91 vs 0.84, p=0.012) and homogeneity index lower (0.20 vs 0.27, p=0.004). Non-coplanar VMAT reduced monitor units by 88.5% (748 vs 6528 MU, p=0.004) and treatment time by 25.2% (287 vs 384 seconds, p=0.004). Bilateral eye D max was 21-27% lower (all p=0.004) and bilateral cochlear D max approximately 15% lower (p ≤ 0.008). Conclusions Non-coplanar VMAT demonstrated superior dosimetric characteristics compared to TomoTherapy for HA-PCI with 3-mm margin, meeting hippocampal constraints while improving target coverage and treatment efficiency. Prospective validation with neurocognitive outcomes is needed.

Frontiers in OncologyVol. 16
St. Mary's Hospital (US), The Catholic University of Korea Seoul St. Mary's Hospital (KR), Catholic University of Korea (KR)
Good health and well-being
Openalex Percentile: Top 13%
Brain Metastases and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.