Echocardiographic Assessment Before, During, and After Impella Positioning: State of the Art

Echocardiographic assessment is essential for evaluating patients with cardiogenic shock (CS) and determining their potential need for mechanical circulatory support (MCS) implantation. The use of Impella devices has increased significantly in recent years, paralleling the growing recognition of their hemodynamic benefits in selected patient populations. As the clinical experience with these devices has expanded, the need for a more standardized imaging approach has emerged. Both transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) play complementary roles in guiding the pre-implantation evaluation, placement procedure, and post-implantation management of Impella devices. Currently, no comprehensive guidelines exist concerning the echocardiographic evaluation of Impella devices throughout their entire clinical course, from initial patient selection and device implantation to ongoing monitoring and eventual weaning. This gap in standardized guidance has led to significant variability in clinical practice across different institutions and healthcare systems. This comprehensive review examines the role of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) in managing patients on Impella support across five distinct phases: candidate identification and pre-implantation assessment, intraoperative procedural guidance and device positioning, postoperative monitoring and haemodynamic optimisation, complication detection and troubleshooting, and weaning strategies with post-explantation surveillance. Both left-sided devices (Impella CP, CP Smart Assist, and Impella 5.5) and right-sided support (Impella RP) are covered, including combined configurations with VA-ECMO (ECPella). For each phase, we detail the recommended echocardiographic views, essential measurements and their evidence-based thresholds, signs of device malposition, and practical corrective strategies. A level-of-evidence approach is adopted throughout, specifying whether proposed thresholds derive from randomised trials, observational studies, expert consensus, or manufacturer recommendations. Summary tables and a bedside workflow are provided to facilitate immediate clinical application.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2026-03-21
DOI
https://doi.org/10.3390/jcm15062404
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Echocardiographic Assessment Before, During, and After Impella Positioning: State of the Art

Edoardo Elia, Gioel Gabrio Secco, Alberto Piermartiri, Rachele Contri et al.
Journal of Clinical Medicine
Mechanical Circulatory Support Devices
article

Echocardiographic Assessment Before, During, and After Impella Positioning: State of the Art

Edoardo Elia, Gioel Gabrio Secco, Alberto Piermartiri, Rachele Contri, Alina Gallo, Andrea Audo, Marta Bandini, Giulia Maj
article en

Abstract

Echocardiographic assessment is essential for evaluating patients with cardiogenic shock (CS) and determining their potential need for mechanical circulatory support (MCS) implantation. The use of Impella devices has increased significantly in recent years, paralleling the growing recognition of their hemodynamic benefits in selected patient populations. As the clinical experience with these devices has expanded, the need for a more standardized imaging approach has emerged. Both transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) play complementary roles in guiding the pre-implantation evaluation, placement procedure, and post-implantation management of Impella devices. Currently, no comprehensive guidelines exist concerning the echocardiographic evaluation of Impella devices throughout their entire clinical course, from initial patient selection and device implantation to ongoing monitoring and eventual weaning. This gap in standardized guidance has led to significant variability in clinical practice across different institutions and healthcare systems. This comprehensive review examines the role of transthoracic echocardiography (TTE) and transesophageal echocardiography (TEE) in managing patients on Impella support across five distinct phases: candidate identification and pre-implantation assessment, intraoperative procedural guidance and device positioning, postoperative monitoring and haemodynamic optimisation, complication detection and troubleshooting, and weaning strategies with post-explantation surveillance. Both left-sided devices (Impella CP, CP Smart Assist, and Impella 5.5) and right-sided support (Impella RP) are covered, including combined configurations with VA-ECMO (ECPella). For each phase, we detail the recommended echocardiographic views, essential measurements and their evidence-based thresholds, signs of device malposition, and practical corrective strategies. A level-of-evidence approach is adopted throughout, specifying whether proposed thresholds derive from randomised trials, observational studies, expert consensus, or manufacturer recommendations. Summary tables and a bedside workflow are provided to facilitate immediate clinical application.

Journal of Clinical MedicineVol. 15(6)
Royal Papworth Hospital (GB), Azienda Ospedaliera Nazionale SS. Antonio e Biagio e Cesare Arrigo (IT), University of Bologna (IT)
Openalex Percentile: Top 12%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.