Augmented Reality and Ultrasonography-Guided Needle Placement: Feasibility and Accuracy in a Phantom Model

Objective: Augmented reality (AR) can improve ultrasonography (US)-guided procedures by placing images in the operator’s line of sight. Published Apple Vision Pro (AVP) US workflows are scarce. This study compared the feasibility and accuracy of an AR US system versus conventional sonography. Materials and Methods: This was designed as a prospective crossover feasibility study. The AR system used a Clarius L15 HD linear transducer streamed to an AVP headset and conventional ultrasound equipment system. Participants placed a 22-gauge spinal needle into eight clay targets (e.g., 0.5–2.0 cm) in a gelatin phantom with both systems. The primary outcome was accuracy (i.e., hits/attempts). Feasibility was assessed with an eight item, 5-point Likert-type survey. The data analyses were completed with descriptive output. Results: Three radiologists experienced in US guidance achieved 23/24 first-pass hits (i.e., 96%) using AR US guidance versus 24/24 (i.e., 100%) with conventional sonography. Ratings for AR US guidance were high for hand-eye coordination (e.g., 5.0 ± 0.0), image stability (e.g., 4.7 ± 0.6), and overall satisfaction (e.g., 4.7 ± 0.6), with greater ease of use than conventional sonography (e.g., 3.3 ± 0.6). The study limitations included visualization (e.g., 2.0 ± 1.7), headset comfort (e.g., 2.3 ± 1.5), and technical reliability (e.g., 2.7 ± 0.6). Conclusion: For this cohort of users, streaming US to AVP, enabled accurate, feasible AR US-guided needle placement with performance comparable to conventional sonography.

Authors

Institutions

Publication Details

Journal
Journal of diagnostic medical sonography
Published
2026-03-23
DOI
https://doi.org/10.1177/87564793261418020
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Augmented Reality and Ultrasonography-Guided Needle Placement: Feasibility and Accuracy in a Phantom Model

Hugue A. Ouellette, Noah Tregobov, Paul I. Mallinson, Philip Edgcumbe et al.
Journal of diagnostic medical sonography
Augmented Reality Applications
article

Augmented Reality and Ultrasonography-Guided Needle Placement: Feasibility and Accuracy in a Phantom Model

Hugue A. Ouellette, Noah Tregobov, Paul I. Mallinson, Philip Edgcumbe, Jin Yan, Abdulaziz A. Alhuwaymil, Peter Munk, Tony Jiang, Afnan Aludaini, Adnan Sheikh
article en

Abstract

Objective: Augmented reality (AR) can improve ultrasonography (US)-guided procedures by placing images in the operator’s line of sight. Published Apple Vision Pro (AVP) US workflows are scarce. This study compared the feasibility and accuracy of an AR US system versus conventional sonography. Materials and Methods: This was designed as a prospective crossover feasibility study. The AR system used a Clarius L15 HD linear transducer streamed to an AVP headset and conventional ultrasound equipment system. Participants placed a 22-gauge spinal needle into eight clay targets (e.g., 0.5–2.0 cm) in a gelatin phantom with both systems. The primary outcome was accuracy (i.e., hits/attempts). Feasibility was assessed with an eight item, 5-point Likert-type survey. The data analyses were completed with descriptive output. Results: Three radiologists experienced in US guidance achieved 23/24 first-pass hits (i.e., 96%) using AR US guidance versus 24/24 (i.e., 100%) with conventional sonography. Ratings for AR US guidance were high for hand-eye coordination (e.g., 5.0 ± 0.0), image stability (e.g., 4.7 ± 0.6), and overall satisfaction (e.g., 4.7 ± 0.6), with greater ease of use than conventional sonography (e.g., 3.3 ± 0.6). The study limitations included visualization (e.g., 2.0 ± 1.7), headset comfort (e.g., 2.3 ± 1.5), and technical reliability (e.g., 2.7 ± 0.6). Conclusion: For this cohort of users, streaming US to AVP, enabled accurate, feasible AR US-guided needle placement with performance comparable to conventional sonography.

Journal of diagnostic medical sonography
University of British Columbia (CA)
Openalex Percentile: Top 11%
Augmented Reality Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.