Prospective single-arm study of gastric surgery in experimental animals assisted by Kangduo surgical robot

Objective: To investigate the feasibility, efficacy, and safety of gastric surgery in experimental animals assisted by the domestic Kangduo Surgical Robot 2000 (SR2000). Methods: Eight porcine models were prospectively enrolled between August and December 2023 at Harbin SAGEBOT Intelligent Medical Animal Experiment Center. Preoperative baseline characteristics, intraoperative physiological parameters, surgical procedure, and postoperative assessments and investigations were recorded to compare the feasibility, efficacy, and safety evaluation indexes of experimental animals in the perioperative period. The primary endpoint was surgical success rate. The secondary endpoints were operative workflow parameters, intraoperative blood loss, postoperative laboratory changes, perioperative adverse events, and surgeon workload assessed using the NASA-TLX instrument. Results: In eight experimental pig models, the SR2000 successfully assisted in the completion of partial gastrectomy. All surgeries were completed according to plan, with no intermediate open or intraoperative complications, and the perioperative survival rate of animals was 100%. The mean operation time of partial gastrectomy was 76.75 min (range: 50–105 min), and the positioning time was 6–17 min. Intraoperative bleeding was ≤5 ml in all the animals, and some animals showed elevated white blood cell counts and neutrophil counts (Neu) on the first day of the postoperative period. The liver and kidney function indexes (alanine aminotransferase, blood urea nitrogen, creatinine) were not significantly abnormal before and after surgery. The anastomosis healed well without complications such as infection and anastomotic fistula. Conclusion: The feasibility, efficacy, and safety of the SR2000 were verified in animal experiments, and ergonomically optimized design have the potential for clinical dissemination.

Authors

Institutions

Publication Details

Journal
International Journal of Surgery
Published
2026-03-23
DOI
https://doi.org/10.1097/js9.0000000000005035
Primary Topic
Minimally Invasive Surgical Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective single-arm study of gastric surgery in experimental animals assisted by Kangduo surgical robot

C. Wang, Yuliuming Wang, Haonan Qi, Ying Jin et al.
International Journal of Surgery
Minimally Invasive Surgical Techniques
article

Prospective single-arm study of gastric surgery in experimental animals assisted by Kangduo surgical robot

C. Wang, Yuliuming Wang, Haonan Qi, Ying Jin, Yong Li, Tianyi Ma, Cong Zhang, Guiyu Wang, Wenyang Li, Songtao Yu, Yunxiao Liu, Tianyu Qiao, Hao Zhang, Ziming Yuan, Bowen Chi, Ruoyu Liu, Zijing Guan
article en

Abstract

Objective: To investigate the feasibility, efficacy, and safety of gastric surgery in experimental animals assisted by the domestic Kangduo Surgical Robot 2000 (SR2000). Methods: Eight porcine models were prospectively enrolled between August and December 2023 at Harbin SAGEBOT Intelligent Medical Animal Experiment Center. Preoperative baseline characteristics, intraoperative physiological parameters, surgical procedure, and postoperative assessments and investigations were recorded to compare the feasibility, efficacy, and safety evaluation indexes of experimental animals in the perioperative period. The primary endpoint was surgical success rate. The secondary endpoints were operative workflow parameters, intraoperative blood loss, postoperative laboratory changes, perioperative adverse events, and surgeon workload assessed using the NASA-TLX instrument. Results: In eight experimental pig models, the SR2000 successfully assisted in the completion of partial gastrectomy. All surgeries were completed according to plan, with no intermediate open or intraoperative complications, and the perioperative survival rate of animals was 100%. The mean operation time of partial gastrectomy was 76.75 min (range: 50–105 min), and the positioning time was 6–17 min. Intraoperative bleeding was ≤5 ml in all the animals, and some animals showed elevated white blood cell counts and neutrophil counts (Neu) on the first day of the postoperative period. The liver and kidney function indexes (alanine aminotransferase, blood urea nitrogen, creatinine) were not significantly abnormal before and after surgery. The anastomosis healed well without complications such as infection and anastomotic fistula. Conclusion: The feasibility, efficacy, and safety of the SR2000 were verified in animal experiments, and ergonomically optimized design have the potential for clinical dissemination.

International Journal of Surgery
Harbin Medical University (CN), Online Technologies (United States) (US), Second Affiliated Hospital of Harbin Medical University (CN)
Good health and well-being
Openalex Percentile: Top 12%
Minimally Invasive Surgical Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.