Stable focusing of proteins within a packed microbead bed by ion concentration polarization in a paper-based analytical device

Paper-based analytical devices (PADs), and particularly lateral flow assays (LFAs), provide many advantages for protein sensing in clinical and resource-limited settings. This class of devices is an important tool for point-of-care (POC) diagnostics, but is limited by sensitivity, which is often inferior to standard benchtop instrumentation. Improvements in sensitivity would increase the range of accessible analytes for biological assays at the POC. Electrokinetic enrichment methods, such as ion concentration polarization focusing (ICPF), have been implemented for target analyte preconcentration. While ICPF has been demonstrated to achieve high enrichment factors (EFs) of proteins in PADs, the focused protein plug experiences instability, leading to bursting (downstream washout) or propagation (gradual upstream displacement) if convective forces are too strong or too weak. Here, we address these challenges by applying a patterned microbead bed to an ICP-PAD. The incorporation of the microbead bed is shown to fix the location of the dye-linked protein enrichment. In contrast, the ICP-PAD without beads exhibits bursting of the focused plug. Besides counteracting bursting, the microbead bed (µb) ICP-PAD increased the average EF by 5-fold and the maximum EF by 4-fold, with a peak EF of over 23-fold. Studies characterizing the effect of bead size were conducted and evaluated using parameters such as EF and the retained fraction of the plug to determine the bead diameters that prevent bursting. To evaluate the stability of the bed, we examined the fluorescence produced by a bed of stained microbeads before and after ICPF, and found less than 1% of fluorescence intensity lost. Finally, we leveraged the microbead bed as a test line for a biotinylated protein in a model LFA. We anticipate that this device architecture is broadly applicable to other real-world systems at the POC. These results establish a platform for the future integration of ICPF with LFAs for stable preconcentration and improved sensitivity of previously inaccessible protein targets.

Authors

Institutions

Publication Details

Journal
The Analyst
Published
2026-01-01
DOI
https://doi.org/10.1039/d6an00004e
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stable focusing of proteins within a packed microbead bed by ion concentration polarization in a paper-based analytical device

Sommer Osman, Kira L. Rahn, Robbyn Kimberly Anand, Quinlan G. Pollak et al.
The Analyst
Biosensors and Analytical Detection
article

Stable focusing of proteins within a packed microbead bed by ion concentration polarization in a paper-based analytical device

Sommer Osman, Kira L. Rahn, Robbyn Kimberly Anand, Quinlan G. Pollak, Md Ruhul Amin
article en

Abstract

Paper-based analytical devices (PADs), and particularly lateral flow assays (LFAs), provide many advantages for protein sensing in clinical and resource-limited settings. This class of devices is an important tool for point-of-care (POC) diagnostics, but is limited by sensitivity, which is often inferior to standard benchtop instrumentation. Improvements in sensitivity would increase the range of accessible analytes for biological assays at the POC. Electrokinetic enrichment methods, such as ion concentration polarization focusing (ICPF), have been implemented for target analyte preconcentration. While ICPF has been demonstrated to achieve high enrichment factors (EFs) of proteins in PADs, the focused protein plug experiences instability, leading to bursting (downstream washout) or propagation (gradual upstream displacement) if convective forces are too strong or too weak. Here, we address these challenges by applying a patterned microbead bed to an ICP-PAD. The incorporation of the microbead bed is shown to fix the location of the dye-linked protein enrichment. In contrast, the ICP-PAD without beads exhibits bursting of the focused plug. Besides counteracting bursting, the microbead bed (µb) ICP-PAD increased the average EF by 5-fold and the maximum EF by 4-fold, with a peak EF of over 23-fold. Studies characterizing the effect of bead size were conducted and evaluated using parameters such as EF and the retained fraction of the plug to determine the bead diameters that prevent bursting. To evaluate the stability of the bed, we examined the fluorescence produced by a bed of stained microbeads before and after ICPF, and found less than 1% of fluorescence intensity lost. Finally, we leveraged the microbead bed as a test line for a biotinylated protein in a model LFA. We anticipate that this device architecture is broadly applicable to other real-world systems at the POC. These results establish a platform for the future integration of ICPF with LFAs for stable preconcentration and improved sensitivity of previously inaccessible protein targets.

The Analyst
Iowa State University (US)
Openalex Percentile: Top 13%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.