Development and preclinical results of a transcatheter aortic valve implant with novel polymeric leaflets

Current transcatheter aortic valve implantation (TAVI) systems use glutaraldehyde-fixed tissue leaflets, which are prone to structural valve degeneration. Polymeric valves may improve durability, hemocompatibility, and manufacturability. We designed, produced, and evaluated a self-expanding nitinol-framed TAVI device with siloxane poly(urethane-urea) (SiPUU) leaflets and an electrospun SiPUU skirt. Bench testing included frame fatigue to 200 million cycles, hydrodynamics per ISO 5840-3, and flow visualization using particle image velocimetry. Biocompatibility was assessed per ISO 10993. Preclinical evaluation involved nine ovine implants with serial imaging and histology to 90 days. In vitro tests showed EOAs of 1.3-1.5 cm² and 1.7-2.1 cm² (21 and 24 mm annulus, respectively, simulating under expansion), regurgitant fraction <6%, and preserved coaptation. Six animals completed follow-up with stable hemodynamics, no hemolysis, no PVL at implant, and no calcification at explant. The SiPUU-based TAVI demonstrated favorable durability, hydrodynamics, and biocompatibility, supporting further testing and delivery refinement toward first-in-human evaluation. Clinical Trial: N/A.

Authors

Institutions

Publication Details

Journal
npj Cardiovascular Health
Published
2026-03-23
DOI
https://doi.org/10.1038/s44325-026-00112-x
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and preclinical results of a transcatheter aortic valve implant with novel polymeric leaflets

Garrett Johnson, Steven Yakubov, J. Ryan Stanfield, Isaac George et al.
npj Cardiovascular Health
Cardiac Valve Diseases and Treatments
article

Development and preclinical results of a transcatheter aortic valve implant with novel polymeric leaflets

Garrett Johnson, Steven Yakubov, J. Ryan Stanfield, Isaac George, Nelson Belais
article en

Abstract

Current transcatheter aortic valve implantation (TAVI) systems use glutaraldehyde-fixed tissue leaflets, which are prone to structural valve degeneration. Polymeric valves may improve durability, hemocompatibility, and manufacturability. We designed, produced, and evaluated a self-expanding nitinol-framed TAVI device with siloxane poly(urethane-urea) (SiPUU) leaflets and an electrospun SiPUU skirt. Bench testing included frame fatigue to 200 million cycles, hydrodynamics per ISO 5840-3, and flow visualization using particle image velocimetry. Biocompatibility was assessed per ISO 10993. Preclinical evaluation involved nine ovine implants with serial imaging and histology to 90 days. In vitro tests showed EOAs of 1.3-1.5 cm² and 1.7-2.1 cm² (21 and 24 mm annulus, respectively, simulating under expansion), regurgitant fraction <6%, and preserved coaptation. Six animals completed follow-up with stable hemodynamics, no hemolysis, no PVL at implant, and no calcification at explant. The SiPUU-based TAVI demonstrated favorable durability, hydrodynamics, and biocompatibility, supporting further testing and delivery refinement toward first-in-human evaluation. Clinical Trial: N/A.

npj Cardiovascular HealthVol. 3(1)
California Institute of Technology (US), OhioHealth (US), NewYork–Presbyterian Hospital (US), University of Utah (US), Columbia University Irving Medical Center (US), Riverside Methodist Hospital (US), Florida Ornithological Society (US)
Openalex Percentile: Top 22%
Cardiac Valve Diseases and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.