ConvU‐NExT: An Asymmetrical Encoder–Decoder for Denoising Low Dose CT

ABSTRACT Low‐dose computed tomography (LDCT) is a medical imaging modality designed to minimize ionizing radiation exposure while maintaining the ability to produce detailed cross‐sectional images. It is particularly valuable in scenarios requiring repeated imaging, such as cancer screening, follow‐up examinations or pediatric diagnostics, where reducing radiation dose is critical to patient safety. For example, to reduce noise by half, four times the radiation dose is required in the slice. The goal is to achieve post‐processed LDCT images with comparable quality to those obtained from standard‐dose CT imaging. We start with a brief overview of the CT procedures and their limitations. Then we introduce a novel denoising method based on an asymmetric integration of the ConvNeXt backbone with the U‐Net architecture. This novel approach obtained 2–3 times less noise than the original LDCT, having a 10%–20% increase in performance compared to U‐Net implementation, checked against three metrics MSE, SSIMLoss and combinations of both. The results suggest that: (i) augmenting the images with specific noise, obtained from water phantom CT scan test, while training yields superior results compared to generic noise augmentations; (ii) a larger kernel size better extracts features and (iii) a smaller kernel size was mandatory for feature reconstruction.

Authors

Institutions

Publication Details

Journal
IET Image Processing
Published
2026-01-01
DOI
https://doi.org/10.1049/ipr2.70317
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

ConvU‐NExT: An Asymmetrical Encoder–Decoder for Denoising Low Dose CT

Sorana Mureșanu, Adrian Groza, Andrei Varan, Radin‐Darius Oniţ et al.
IET Image Processing
Medical Imaging Techniques and Applications
article

ConvU‐NExT: An Asymmetrical Encoder–Decoder for Denoising Low Dose CT

Sorana Mureșanu, Adrian Groza, Andrei Varan, Radin‐Darius Oniţ, TEAM Project Group, Liviu‐Mihai Iacob, Mihaela Hedeşiu
article en

Abstract

ABSTRACT Low‐dose computed tomography (LDCT) is a medical imaging modality designed to minimize ionizing radiation exposure while maintaining the ability to produce detailed cross‐sectional images. It is particularly valuable in scenarios requiring repeated imaging, such as cancer screening, follow‐up examinations or pediatric diagnostics, where reducing radiation dose is critical to patient safety. For example, to reduce noise by half, four times the radiation dose is required in the slice. The goal is to achieve post‐processed LDCT images with comparable quality to those obtained from standard‐dose CT imaging. We start with a brief overview of the CT procedures and their limitations. Then we introduce a novel denoising method based on an asymmetric integration of the ConvNeXt backbone with the U‐Net architecture. This novel approach obtained 2–3 times less noise than the original LDCT, having a 10%–20% increase in performance compared to U‐Net implementation, checked against three metrics MSE, SSIMLoss and combinations of both. The results suggest that: (i) augmenting the images with specific noise, obtained from water phantom CT scan test, while training yields superior results compared to generic noise augmentations; (ii) a larger kernel size better extracts features and (iii) a smaller kernel size was mandatory for feature reconstruction.

IET Image ProcessingVol. 20(1)
Technical University of Cluj-Napoca (RO), Iuliu Hațieganu University of Medicine and Pharmacy (RO), Babeș-Bolyai University (RO)
Good health and well-being
Openalex Percentile: Top 14%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.