Femtosecond Laser Micropore-Enhanced Miniaturised PCB-Based Microbial Fuel Cell Biosensor for Toxicity Detection

This study presents a low-cost, small-scale single-chamber microbial fuel cell (MFC) toxicity biosensor fabricated on a printed circuit board (PCB) and a 3D-printed chamber with a volume of 120 μL. The anode consists of a screen-printed carbon electrode on the PCB, while the air cathode is a carbon paper electrode. To address poor adhesion of microorganisms to the smooth anode surface, femtosecond laser processing was used to fabricate a micropore array with 40 μm pores on the electrode. This method can create micropores on the anode surface without damaging the screen-printed electrodes, the PCB substrate, or the pads. These micropores increase the anode's surface area and hydrophilicity, allowing more microbial coatings to firmly adhere to its surface. In this study, the MFC utilised <i>Rhizobium rosettiformans</i> W3, extracted from activated sludge at a wastewater treatment plant, as the anode microorganism. Its aerobic nature simplifies the design of MFCs, enabling a single-chamber structure and miniaturisation. Using formaldehyde solution as a toxicity sample to test the biosensor's performance, a 0.1% concentration significantly reduced the sensor's output power.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-03-22
DOI
https://doi.org/10.3390/bios16030179
Primary Topic
Microbial Fuel Cells and Bioremediation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Femtosecond Laser Micropore-Enhanced Miniaturised PCB-Based Microbial Fuel Cell Biosensor for Toxicity Detection

Zhongxian Li, Ningran Wang, Wenbin Zhang, Lijuan Liang et al.
Biosensors
Microbial Fuel Cells and Bioremediation
article

Femtosecond Laser Micropore-Enhanced Miniaturised PCB-Based Microbial Fuel Cell Biosensor for Toxicity Detection

Zhongxian Li, Ningran Wang, Wenbin Zhang, Lijuan Liang, Tong Qi, Hebin Sun, Jianlong Zhao
article en

Abstract

This study presents a low-cost, small-scale single-chamber microbial fuel cell (MFC) toxicity biosensor fabricated on a printed circuit board (PCB) and a 3D-printed chamber with a volume of 120 μL. The anode consists of a screen-printed carbon electrode on the PCB, while the air cathode is a carbon paper electrode. To address poor adhesion of microorganisms to the smooth anode surface, femtosecond laser processing was used to fabricate a micropore array with 40 μm pores on the electrode. This method can create micropores on the anode surface without damaging the screen-printed electrodes, the PCB substrate, or the pads. These micropores increase the anode's surface area and hydrophilicity, allowing more microbial coatings to firmly adhere to its surface. In this study, the MFC utilised <i>Rhizobium rosettiformans</i> W3, extracted from activated sludge at a wastewater treatment plant, as the anode microorganism. Its aerobic nature simplifies the design of MFCs, enabling a single-chamber structure and miniaturisation. Using formaldehyde solution as a toxicity sample to test the biosensor's performance, a 0.1% concentration significantly reduced the sensor's output power.

BiosensorsVol. 16(3)
Chinese Academy of Sciences (CN), ShanghaiTech University (CN), State Key Laboratory of Transducer Technology (CN), Shanghai Institute of Microsystem and Information Technology (CN), University of Chinese Academy of Sciences (CN)
Clean water and sanitation
Openalex Percentile: Top 12%
Microbial Fuel Cells and Bioremediation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Femtosecond Laser Micropore-Enhanced Miniaturised PCB-Based Microbial Fuel Cell Biosensor for Toxicity Detection — Zhongxian Li, Ningran Wang, et al. · Biosensors (2026) | TGRS Research Map | TGRS