Impact of triple contact lines and interface instabilities on heat-transfer in a vertical grooved plate falling film evaporator at subatmospheric pressure

Falling film evaporators are preferred to flooded evaporators in thermal units using water as a refrigerant, as they offer higher heat and mass transfer performance at operating pressures significantly lower than atmospheric pressure (⁓ 10 mbar). In order to further enhance heat and mass transfer in falling-film evaporator, an experimental and numerical study of thermal performances obtained on a grooved plate-type heat exchanger using distilled water as working fluid was carried out at absolute pressure ranging from 13 mbar to 23 mbar, logarithmic mean temperature difference ranging from 1 to 14 K and Reynolds numbers from 80 to 460 (conditions representatives to conditions obtained in thermal systems using water as refrigerant).The impact of the triple contact line evaporation and the development of interface instabilities on obtained thermal performances are discussed based on experimental data and data obtained from three different simple models based on steady state thermal energy balance. It is shown that heat transfer to triple lines plays a major role in the performance of grooved plate evaporators, accounting for 40 to 50% of transfers for a Reynolds number included between 100 and 400. The intensification factor due the development of waves could reach 10% at Re = 500. Models allow to predict the performances with a relative difference with experimental data standing at 8% for Re around 388. • Experimental data are obtained on a vertical grooved plate falling film evaporator. • Experiments were conducted at absolute pressure ranging from 13 to 23 mbar. • Time-evolution of film thickness is measured at different positions in the grooves. • Intensification factor due to film thickness reduction is estimated. • Impact of triple lines on heat transfer characterized for different interface geometries.

Authors

Institutions

Publication Details

Journal
Applied Thermal Engineering
Published
2026-03-24
DOI
https://doi.org/10.1016/j.applthermaleng.2026.130690
Primary Topic
Fluid Dynamics and Thin Films
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of triple contact lines and interface instabilities on heat-transfer in a vertical grooved plate falling film evaporator at subatmospheric pressure

Florine Giraud, Justine Senechal, Benoît Stutz
Applied Thermal Engineering
Fluid Dynamics and Thin Films
article

Impact of triple contact lines and interface instabilities on heat-transfer in a vertical grooved plate falling film evaporator at subatmospheric pressure

Florine Giraud, Justine Senechal, Benoît Stutz
article en

Abstract

Falling film evaporators are preferred to flooded evaporators in thermal units using water as a refrigerant, as they offer higher heat and mass transfer performance at operating pressures significantly lower than atmospheric pressure (⁓ 10 mbar). In order to further enhance heat and mass transfer in falling-film evaporator, an experimental and numerical study of thermal performances obtained on a grooved plate-type heat exchanger using distilled water as working fluid was carried out at absolute pressure ranging from 13 mbar to 23 mbar, logarithmic mean temperature difference ranging from 1 to 14 K and Reynolds numbers from 80 to 460 (conditions representatives to conditions obtained in thermal systems using water as refrigerant).The impact of the triple contact line evaporation and the development of interface instabilities on obtained thermal performances are discussed based on experimental data and data obtained from three different simple models based on steady state thermal energy balance. It is shown that heat transfer to triple lines plays a major role in the performance of grooved plate evaporators, accounting for 40 to 50% of transfers for a Reynolds number included between 100 and 400. The intensification factor due the development of waves could reach 10% at Re = 500. Models allow to predict the performances with a relative difference with experimental data standing at 8% for Re around 388. • Experimental data are obtained on a vertical grooved plate falling film evaporator. • Experiments were conducted at absolute pressure ranging from 13 to 23 mbar. • Time-evolution of film thickness is measured at different positions in the grooves. • Intensification factor due to film thickness reduction is estimated. • Impact of triple lines on heat transfer characterized for different interface geometries.

Applied Thermal EngineeringVol. 296
Centre National de la Recherche Scientifique (FR), Laboratoire Optimisation de la Conception et Ingénierie de l'Environnement (FR), Université Savoie Mont Blanc (FR)
Climate action
Openalex Percentile: Top 10%
Fluid Dynamics and Thin Films
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.