Establishment and Validation of a Rapid ERA Detection Method for Vibrio parahaemolyticus in Exported Aquatic Products

To address the issues of operational complexity, long duration association, and reliance on specialized equipment with existing detection methods for <i>Vibrio parahaemolyticus</i>, this study established a rapid detection method for <i>V. parahaemolyticus</i> in exported aquatic products based on the domestically developed Enzymatic Recombinase Amplification (ERA) technology. To target the thermolabile hemolysin gene (<i>tlh</i>) and the iron-regulated virulence regulatory protein gene (<i>irgB</i>) of <i>V. parahaemolyticus</i>, highly specific ERA primers and probes were designed and screened. Two detection platforms, a colorimetric method and a fluorescent method, were developed. Method validation results showed that this detection system achieved specific amplification for all 30 tested <i>V. parahaemolyticus</i> strains, with no cross-reactivity observed with 30 other common foodborne pathogenic bacteria. The detection sensitivity for both the fluorescent and colorimetric methods reached 10<sup>-1</sup> ng/μL, with a minimum detection limit of 10 CFU/25 g for artificially contaminated samples. The entire detection process, including sample preparation, requires only approximately 20 min-significantly faster than traditional culture (24-72 h) or even conventional PCR methods. Collaborative validation across five independent laboratories confirmed excellent reproducibility, with inter-laboratory agreement yielding a Kappa coefficient of 0.98. The ERA method operates at a low, constant temperature (37-39 °C), eliminating the need for thermal cyclers. When combined with portable isothermal amplification devices and visual (colorimetric) readout, it offers a distinct advantage in terms of speed, cost-effectiveness, and suitability for resource-limited or field settings compared to existing PCR-based or culture-based platforms. This method is simple to operate, rapid, sensitive, and highly suitable for on-site application, providing a reliable and practical technical solution for the rapid screening and risk monitoring of <i>V. parahaemolyticus</i> in exported aquatic products.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2026-03-21
DOI
https://doi.org/10.3390/bios16030176
Primary Topic
Vibrio bacteria research studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Establishment and Validation of a Rapid ERA Detection Method for Vibrio parahaemolyticus in Exported Aquatic Products

Y. H. Wang, Ying Liang, Feng Xue, Jiahua Wang
Biosensors
Vibrio bacteria research studies
article

Establishment and Validation of a Rapid ERA Detection Method for Vibrio parahaemolyticus in Exported Aquatic Products

Y. H. Wang, Ying Liang, Feng Xue, Jiahua Wang
article en

Abstract

To address the issues of operational complexity, long duration association, and reliance on specialized equipment with existing detection methods for <i>Vibrio parahaemolyticus</i>, this study established a rapid detection method for <i>V. parahaemolyticus</i> in exported aquatic products based on the domestically developed Enzymatic Recombinase Amplification (ERA) technology. To target the thermolabile hemolysin gene (<i>tlh</i>) and the iron-regulated virulence regulatory protein gene (<i>irgB</i>) of <i>V. parahaemolyticus</i>, highly specific ERA primers and probes were designed and screened. Two detection platforms, a colorimetric method and a fluorescent method, were developed. Method validation results showed that this detection system achieved specific amplification for all 30 tested <i>V. parahaemolyticus</i> strains, with no cross-reactivity observed with 30 other common foodborne pathogenic bacteria. The detection sensitivity for both the fluorescent and colorimetric methods reached 10<sup>-1</sup> ng/μL, with a minimum detection limit of 10 CFU/25 g for artificially contaminated samples. The entire detection process, including sample preparation, requires only approximately 20 min-significantly faster than traditional culture (24-72 h) or even conventional PCR methods. Collaborative validation across five independent laboratories confirmed excellent reproducibility, with inter-laboratory agreement yielding a Kappa coefficient of 0.98. The ERA method operates at a low, constant temperature (37-39 °C), eliminating the need for thermal cyclers. When combined with portable isothermal amplification devices and visual (colorimetric) readout, it offers a distinct advantage in terms of speed, cost-effectiveness, and suitability for resource-limited or field settings compared to existing PCR-based or culture-based platforms. This method is simple to operate, rapid, sensitive, and highly suitable for on-site application, providing a reliable and practical technical solution for the rapid screening and risk monitoring of <i>V. parahaemolyticus</i> in exported aquatic products.

BiosensorsVol. 16(3)
Nanjing Agricultural University (CN), Sanya University (CN), China Jiliang University (CN)
Openalex Percentile: Top 11%
Vibrio bacteria research studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.