Outcomes and Complications of Suture-Button versus All-Suture Suspensionplasty in Thumb Carpometacarpal Arthritis: A Retrospective Comparative Study

<b>Background:</b> Our objective is to compare clinical, radiographic and complication-related outcomes between two non-autologous implants - Mini TightRope<sup>®</sup> and Microlink™ - used in suspensionplasty following open trapeziectomy for thumb carpometacarpal joint arthritis. <b>Methods:</b> We retrospectively analysed 77 patients (41 Mini TightRope<sup>®</sup>, 36 Microlink™) treated between 2017 and 2021 with a minimum follow-up of 36 months. All surgeries were performed by the same experienced hand surgeon using a standardised open technique. Pre- and postoperative assessments included Quick Disabilities of the Arm, Shoulder and Hand (QDASH), visual analogue scale (VAS; rest and effort), Kapandji score, grip and pinch strength, thumb range of motion (ROM), patient satisfaction and radiographic evaluation for metacarpal subsidence. Complications and reoperations were recorded and compared. <b>Results:</b> Both groups demonstrated significant clinical improvement, with no statistically significant differences in functional scores, ROM, strength, pain or satisfaction. Implant-related complications differed notably: four Mini TightRope<sup>®</sup> patients (9.8%) required implant removal due to discomfort, and one experienced a transient sensory neurapraxia, yielding a total complication rate of 12.2%. In the Microlink™ group, only one patient (2.8%) experienced a similar neurapraxia, and no implant removals or reoperations were needed. No subsidence was observed in either group. <b>Conclusions:</b> Both implants were clinically effective, but the Microlink™ device was associated with a lower complication rate and no removals. These findings suggest that all-suture implants may offer improved soft-tissue compatibility. This is the first clinical report on Microlink™, and its mid-term results appear comparable to those of the more established Mini TightRope<sup>®</sup>. Further prospective studies are warranted to assess long-term outcomes. <b>Level of Evidence:</b> Level III (Therapeutic).

Authors

Institutions

Publication Details

Journal
The Journal of Hand Surgery (Asian-Pacific Volume)
Published
2026-03-20
DOI
https://doi.org/10.1142/s2424835526500153
Primary Topic
Orthopedic Surgery and Rehabilitation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Outcomes and Complications of Suture-Button versus All-Suture Suspensionplasty in Thumb Carpometacarpal Arthritis: A Retrospective Comparative Study

Gerardo Méndez-Sánchez, Tryno Muñoz-Perdomo, Melissa Bonilla-Chaperon, Sergi Barrera-Ochoa et al.
The Journal of Hand Surgery (Asian-Pacific Volume)
Orthopedic Surgery and Rehabilitation
article

Outcomes and Complications of Suture-Button versus All-Suture Suspensionplasty in Thumb Carpometacarpal Arthritis: A Retrospective Comparative Study

Gerardo Méndez-Sánchez, Tryno Muñoz-Perdomo, Melissa Bonilla-Chaperon, Sergi Barrera-Ochoa, Gustavo SOSA-VIAIN
article en

Abstract

<b>Background:</b> Our objective is to compare clinical, radiographic and complication-related outcomes between two non-autologous implants - Mini TightRope<sup>®</sup> and Microlink™ - used in suspensionplasty following open trapeziectomy for thumb carpometacarpal joint arthritis. <b>Methods:</b> We retrospectively analysed 77 patients (41 Mini TightRope<sup>®</sup>, 36 Microlink™) treated between 2017 and 2021 with a minimum follow-up of 36 months. All surgeries were performed by the same experienced hand surgeon using a standardised open technique. Pre- and postoperative assessments included Quick Disabilities of the Arm, Shoulder and Hand (QDASH), visual analogue scale (VAS; rest and effort), Kapandji score, grip and pinch strength, thumb range of motion (ROM), patient satisfaction and radiographic evaluation for metacarpal subsidence. Complications and reoperations were recorded and compared. <b>Results:</b> Both groups demonstrated significant clinical improvement, with no statistically significant differences in functional scores, ROM, strength, pain or satisfaction. Implant-related complications differed notably: four Mini TightRope<sup>®</sup> patients (9.8%) required implant removal due to discomfort, and one experienced a transient sensory neurapraxia, yielding a total complication rate of 12.2%. In the Microlink™ group, only one patient (2.8%) experienced a similar neurapraxia, and no implant removals or reoperations were needed. No subsidence was observed in either group. <b>Conclusions:</b> Both implants were clinically effective, but the Microlink™ device was associated with a lower complication rate and no removals. These findings suggest that all-suture implants may offer improved soft-tissue compatibility. This is the first clinical report on Microlink™, and its mid-term results appear comparable to those of the more established Mini TightRope<sup>®</sup>. Further prospective studies are warranted to assess long-term outcomes. <b>Level of Evidence:</b> Level III (Therapeutic).

The Journal of Hand Surgery (Asian-Pacific Volume)Vol. 31(02)
Clínica Girona (ES), Hospital General de Catalunya (ES), Hospital Comarcal de Inca (ES)
Openalex Percentile: Top 13%
Orthopedic Surgery and Rehabilitation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.