When Blue Turns the Green Off: Implications of Methylene Blue Interference in Indocyanine Green Near-Infrared Fluorescence Imaging

Sentinel lymph node mapping is increasingly used in canine and feline oncology and often involves the combined use of visible dyes and fluorescent tracers. However, the effect of methylene blue on the fluorescence of indocyanine green during near-infrared imaging remains unclear. This explorative study aimed to quantitatively and qualitatively assess potential fluorescence quenching in solutions of methylene blue-indocyanine green at different ratios in three near-infrared imaging modalities (overlay, color map, contrast). Four solutions were prepared: 100%/0%, 75%/25%, 50%/50%, and 25%/75% indocyanine green/methylene blue. The fluorescence intensity of the four solutions was quantitatively measured in vitro using near-infrared imaging. Subsequently, four lymphographies, one for each solution, were performed from the metatarsal region of feline cadavers. Observers with varying levels of experience evaluated lymphographic images. Methylene blue caused a concentration-dependent reduction in fluorescence both at the quantitative evaluation and qualitative lymphography interpretation. Despite this reduction, fluorescence remained sufficient in cadavers for accurate identification of lymph nodes, and observer experience did not significantly affect interpretation, except for the color map mode. Because methylene blue-dominant solutions showed a greater quenching effect on indocyanine green fluorescence, clinicians should favor indocyanine green-dominant mixtures. This approach may preserve fluorescence performance, maintaining the surgical guidance benefits of methylene blue. Future confirmatory studies should include a substantially larger number of specimens to allow appropriate statistical comparisons and to better account for inter-individual variability.

Authors

Institutions

Publication Details

Journal
Animals
Published
2026-03-21
DOI
https://doi.org/10.3390/ani16060983
Primary Topic
Breast Implant and Reconstruction
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

When Blue Turns the Green Off: Implications of Methylene Blue Interference in Indocyanine Green Near-Infrared Fluorescence Imaging

Luigi Auletta, Roberta Ferrari, Damiano Stefanello, Alessandra Ubiali et al.
Animals
Breast Implant and Reconstruction
article

When Blue Turns the Green Off: Implications of Methylene Blue Interference in Indocyanine Green Near-Infrared Fluorescence Imaging

Luigi Auletta, Roberta Ferrari, Damiano Stefanello, Alessandra Ubiali, Elisa Maria Gariboldi
article en

Abstract

Sentinel lymph node mapping is increasingly used in canine and feline oncology and often involves the combined use of visible dyes and fluorescent tracers. However, the effect of methylene blue on the fluorescence of indocyanine green during near-infrared imaging remains unclear. This explorative study aimed to quantitatively and qualitatively assess potential fluorescence quenching in solutions of methylene blue-indocyanine green at different ratios in three near-infrared imaging modalities (overlay, color map, contrast). Four solutions were prepared: 100%/0%, 75%/25%, 50%/50%, and 25%/75% indocyanine green/methylene blue. The fluorescence intensity of the four solutions was quantitatively measured in vitro using near-infrared imaging. Subsequently, four lymphographies, one for each solution, were performed from the metatarsal region of feline cadavers. Observers with varying levels of experience evaluated lymphographic images. Methylene blue caused a concentration-dependent reduction in fluorescence both at the quantitative evaluation and qualitative lymphography interpretation. Despite this reduction, fluorescence remained sufficient in cadavers for accurate identification of lymph nodes, and observer experience did not significantly affect interpretation, except for the color map mode. Because methylene blue-dominant solutions showed a greater quenching effect on indocyanine green fluorescence, clinicians should favor indocyanine green-dominant mixtures. This approach may preserve fluorescence performance, maintaining the surgical guidance benefits of methylene blue. Future confirmatory studies should include a substantially larger number of specimens to allow appropriate statistical comparisons and to better account for inter-individual variability.

AnimalsVol. 16(6)
University of Milan (IT)
Openalex Percentile: Top 13%
Breast Implant and Reconstruction
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.