Seasonal assessment of water pollution in the Hindon River with reference to physico-chemical, microbial and Heavy metal contamination

The Hindon River is considered one of the major branches of the River Yamuna in the plain region. The river is utilized as a major water source in the populated rural area of western Uttar Pradesh. Due to the dense agricultural and industrial activity along the river, the river is becoming highly polluted. The current study involves the estimation of the water quality of the Hindon River at selected sampling locations by monitoring the physicochemical, heavy metal, and microbiological parameters. Water samples from selected sites (Town-Budhana, District-Muzaffarnagar, Village-Baparsi, District-Meerut, and Village-Surana, District-Ghaziabad) were collected in triplicate in the seasons of pre-monsoon, monsoon, and post-monsoon during the year 2022-2023. Physicochemical analysis revealed significant pollution across all the sampling locations. The pH and temperature varied from 6.79 to 7.89 and 25.97 to 30.23°C, respectively, across all sites. Electrical conductivity ranged from 737.4 to 1113.34 µS/cm, color ranged from 12 to 32 Hazen, TDS ranged from 528 to 765 mg/L, TSS ranged from 65.7 to 241.67 mg/L, and turbidity ranged from 23.70 to 55.26 NTU. The range of alkalinity was 346.7 to 633.33 mg/L, dissolved oxygen was 0.76 to 4.30 mg/L, BOD was 25.0 to 206.67 mg/L, and COD was 82.0 to 456.67 mg/L. The ranges for total hardness were 316.7 to 513.33 mg/L, sulfate 12.96 to 26.16 mg/L, nitrate 8.52 to 26.98 mg/L, fluoride 0.14 to 0.44 mg/L, and total coliforms 1.43 to 4.07 × 10⁻² MPN/100 mL. E. coli was found in every sample. Sampling site-3 was found with the highest level of contamination with high ecological risk. The results show that water from the Hindon River is unsuitable for consumption and requires potential control measures.

Authors

Institutions

Publication Details

Journal
Environment Conservation Journal
Published
2026-02-26
DOI
https://doi.org/10.36953/ecj.33783124
Primary Topic
Water Quality and Pollution Assessment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Seasonal assessment of water pollution in the Hindon River with reference to physico-chemical, microbial and Heavy metal contamination

Arun Sharma, Dhruv Kumar, Laxmi Kant Bhardwaj, Swapnil Rai et al.
Environment Conservation Journal
Water Quality and Pollution Assessment
article

Seasonal assessment of water pollution in the Hindon River with reference to physico-chemical, microbial and Heavy metal contamination

Arun Sharma, Dhruv Kumar, Laxmi Kant Bhardwaj, Swapnil Rai, Kuldeep Dwivedi, Hariom Tyagi
article en

Abstract

The Hindon River is considered one of the major branches of the River Yamuna in the plain region. The river is utilized as a major water source in the populated rural area of western Uttar Pradesh. Due to the dense agricultural and industrial activity along the river, the river is becoming highly polluted. The current study involves the estimation of the water quality of the Hindon River at selected sampling locations by monitoring the physicochemical, heavy metal, and microbiological parameters. Water samples from selected sites (Town-Budhana, District-Muzaffarnagar, Village-Baparsi, District-Meerut, and Village-Surana, District-Ghaziabad) were collected in triplicate in the seasons of pre-monsoon, monsoon, and post-monsoon during the year 2022-2023. Physicochemical analysis revealed significant pollution across all the sampling locations. The pH and temperature varied from 6.79 to 7.89 and 25.97 to 30.23°C, respectively, across all sites. Electrical conductivity ranged from 737.4 to 1113.34 µS/cm, color ranged from 12 to 32 Hazen, TDS ranged from 528 to 765 mg/L, TSS ranged from 65.7 to 241.67 mg/L, and turbidity ranged from 23.70 to 55.26 NTU. The range of alkalinity was 346.7 to 633.33 mg/L, dissolved oxygen was 0.76 to 4.30 mg/L, BOD was 25.0 to 206.67 mg/L, and COD was 82.0 to 456.67 mg/L. The ranges for total hardness were 316.7 to 513.33 mg/L, sulfate 12.96 to 26.16 mg/L, nitrate 8.52 to 26.98 mg/L, fluoride 0.14 to 0.44 mg/L, and total coliforms 1.43 to 4.07 × 10⁻² MPN/100 mL. E. coli was found in every sample. Sampling site-3 was found with the highest level of contamination with high ecological risk. The results show that water from the Hindon River is unsuitable for consumption and requires potential control measures.

Environment Conservation JournalVol. 27(1)
Amity University (IN), Uttarakhand Ayurved University (IN), Amity University (AE)
Clean water and sanitation
Openalex Percentile: Top 13%
Water Quality and Pollution Assessment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.