First dual-center clinical experience with the premounted Vienna transcatheter aortic valve system: a prospective feasibility and safety study
Transcatheter aortic valve implantation has become the preferred treatment for many patients with severe aortic stenosis. The Vienna valve is a next-generation, premounted self-expandable transcatheter heart valve designed to simplify procedural workflow and enhance deployment accuracy. To evaluate the feasibility, procedural safety, and early clinical and hemodynamic outcomes of the Vienna transcatheter aortic valve system in patients with severe symptomatic aortic stenosis. This prospective, dual-center observational study enrolled 13 consecutive patients with severe symptomatic aortic stenosis who underwent transfemoral TAVI using the Vienna valve between February 2024 and July 2025. Clinical and echocardiographic assessments were performed at baseline, post-procedure, and during follow-up at 1 and 6 months. Primary endpoints were mortality, stroke, bleeding, pacemaker requirement, rehospitalization, and functional improvement. Outcomes were defined according to Valve Academic Research Consortium-3 criteria. The mean patient age was 72 ± 9 years, and the mean EuroSCORE II was 6.7 ± 4.7%. Procedural success was achieved in 12 of 13 patients (92.3%). One intraprocedural cardiovascular death occurred following valve infolding during repositioning, with associated cardiac tamponade. One additional non-cardiovascular death occurred during follow-up. Mean transvalvular gradient decreased from 45.2 ± 19.0 mmHg at baseline to 9.08 ± 3.7 mmHg immediately post-procedure and remained stable at 6 months (11.9 ± 4.3 mmHg). Mild paravalvular regurgitation was observed in 7 of 12 evaluable patients (58.3%) post-procedure. Six-month MACE occurred in 3 of 12 patients (25.0%). One patient (8.3%) required permanent pacemaker implantation for high-grade atrioventricular block during follow-up. No strokes, major bleeding events, or valve-related rehospitalizations were observed through 6 months. In this initial two-center experience of 13 patients, the premounted Vienna valve demonstrated technical feasibility and favorable early hemodynamic performance. Given one intraprocedural death and a 6-month MACE rate of 25%, larger comparative studies are needed to confirm its safety, performance and durability.
Authors
- Najme‐Sadat Moosavi (ORCID: https://orcid.org/0000-0002-6413-234X)
- Mojtaba Salarifar (ORCID: https://orcid.org/0000-0002-6422-8333)
- Yaser Jenab (ORCID: https://orcid.org/0000-0002-8291-8637)
- Mohammad Alidoosti (ORCID: https://orcid.org/0000-0001-5927-6376)
- Ata Firouzi (ORCID: https://orcid.org/0000-0002-4092-641X)
- Reza Nikfar (ORCID: https://orcid.org/0009-0006-7511-1372)
- Fatemeh Bahreini (ORCID: https://orcid.org/0000-0003-4444-1206)
- Armin Elahifar (ORCID: https://orcid.org/0000-0001-5667-3077)
- Maede Mehdizadeh (ORCID: https://orcid.org/0009-0000-2708-8530)
- Arezoo Zoroufian
- Reza Mohseni
Institutions
- Iran University of Medical Sciences (IR)
- Shaheed Rajaei Cardiovascular Medical and Research Center (IR)
- Tehran Heart Center (IR)
- Cardiovascular Diseases Research Institute (IR)
- Tehran University of Medical Sciences (IR)
Publication Details
- Journal
- BMC Cardiovascular Disorders
- Published
- 2026-11-26
- DOI
- https://doi.org/10.1186/s12872-026-07014-x
- Primary Topic
- Cardiac Valve Diseases and Treatments
- Type
- article
- Field-Weighted Citation Impact
- 0.00