Comparing Manual and Verion Image-guided Marking Methods in Toric Intraocular Lens Implantation: A Vector Analysis Study

Aim: To compare slit-lamp manual marking and Verion imageguidedmarking in toric intraocular lens (IOL) implantation usingvector analysis.Material and Method: Eyes with manual marking were defined asgroup 1 and eyes with Verion image-guided marking were definedas group 2. Target-induced and surgically induced astigmatism,the magnitude and angle of error, the success index, toric IOL rotation,and refractive outcomes were compared.Results: A total of 67 eyes were examined, with 37 in group 1 and30 in group 2. Higher degrees of IOL rotation (≥10°) were predominantlyobserved in the manual marking group. Group 2 had a lowertoric IOL rotation in eyes with against-the-rule astigmatism than ingroup 1 (P=0.003). In Group 2, error size was negatively correlatedwith refractive astigmatism (r=−0.37, P=0.04), whereas the angleof error was positively correlated with best-corrected visual acuity(r=0.526, P=0.003).Conclusion: Vectorial analysis shows that digital marking is moreeffective and yields more predictable outcomes for toric IOL rotationcompared to manual marking, particularly in eyes withagainst-the-rule astigmatism and high astigmatism. This improvedpredictability is attributed to more accurate axis alignment.

Authors

Institutions

Publication Details

Journal
DergiPark (Istanbul University)
Published
2025-04-14
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparing Manual and Verion Image-guided Marking Methods in Toric Intraocular Lens Implantation: A Vector Analysis Study

Ziya Ayhan, Mahmut Kaya, Ata Ozturk, Aylin Yaman et al.
DergiPark (Istanbul University)
Ophthalmology and Visual Impairment Studies
article

Comparing Manual and Verion Image-guided Marking Methods in Toric Intraocular Lens Implantation: A Vector Analysis Study

Ziya Ayhan, Mahmut Kaya, Ata Ozturk, Aylin Yaman, Ezgi Karataş
article en

Abstract

Aim: To compare slit-lamp manual marking and Verion imageguidedmarking in toric intraocular lens (IOL) implantation usingvector analysis.Material and Method: Eyes with manual marking were defined asgroup 1 and eyes with Verion image-guided marking were definedas group 2. Target-induced and surgically induced astigmatism,the magnitude and angle of error, the success index, toric IOL rotation,and refractive outcomes were compared.Results: A total of 67 eyes were examined, with 37 in group 1 and30 in group 2. Higher degrees of IOL rotation (≥10°) were predominantlyobserved in the manual marking group. Group 2 had a lowertoric IOL rotation in eyes with against-the-rule astigmatism than ingroup 1 (P=0.003). In Group 2, error size was negatively correlatedwith refractive astigmatism (r=−0.37, P=0.04), whereas the angleof error was positively correlated with best-corrected visual acuity(r=0.526, P=0.003).Conclusion: Vectorial analysis shows that digital marking is moreeffective and yields more predictable outcomes for toric IOL rotationcompared to manual marking, particularly in eyes withagainst-the-rule astigmatism and high astigmatism. This improvedpredictability is attributed to more accurate axis alignment.

DergiPark (Istanbul University)
Izmir University (TR), Dokuz Eylül University (TR), Ağrı İbrahim Çeçen University (TR)
Openalex Percentile: Top 24%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.