Duplex Reverse Transcription Loop-Mediated Isothermal Amplification on a Nanofluidic Digital Chip (Nano-dChip)

Over the past decades, the frequency of viral outbreaks has increased substantially worldwide, driven in part by global travel and resulting in millions of deaths each year. This trend underscores the urgent need for rapid, simple, and accessible diagnostic tools for infectious disease detection. Here, we present a nanofluidic digital chip (Nano-dChip) for point-of-care viral RNA detection that delivers results within 30 minutes at a cost of less than $0.50 per chip. The Nano-dChip employs reverse transcription loop-mediated isothermal amplification (RT-LAMP) for highly sensitive and specific target amplification. Reaction reagents are compartmentalized into numerous nanofluidic reservoirs, enabling highly quantitative detection while minimizing contamination risks. Using a single chip, we successfully detect both SARS-CoV-2 and Influenza H3 RNA with a detection limit of 10 fM, demonstrating the Nano-dChip's potential as a rapid, low-cost, and scalable diagnostic platform for timely outbreak control.

Authors

Institutions

Publication Details

Journal
bioRxiv (Cold Spring Harbor Laboratory)
Published
2026-03-20
DOI
https://doi.org/10.64898/2026.03.18.712394
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Duplex Reverse Transcription Loop-Mediated Isothermal Amplification on a Nanofluidic Digital Chip (Nano-dChip)

L. L. Liu, Gregory J. Tobin, Juhong Chen, Esmeralda Ruiz-Garcia et al.
bioRxiv (Cold Spring Harbor Laboratory)
Biosensors and Analytical Detection
article

Duplex Reverse Transcription Loop-Mediated Isothermal Amplification on a Nanofluidic Digital Chip (Nano-dChip)

L. L. Liu, Gregory J. Tobin, Juhong Chen, Esmeralda Ruiz-Garcia, Ke Du, Steve Jeffrey Dollery, Natalie Luu
article en

Abstract

Over the past decades, the frequency of viral outbreaks has increased substantially worldwide, driven in part by global travel and resulting in millions of deaths each year. This trend underscores the urgent need for rapid, simple, and accessible diagnostic tools for infectious disease detection. Here, we present a nanofluidic digital chip (Nano-dChip) for point-of-care viral RNA detection that delivers results within 30 minutes at a cost of less than $0.50 per chip. The Nano-dChip employs reverse transcription loop-mediated isothermal amplification (RT-LAMP) for highly sensitive and specific target amplification. Reaction reagents are compartmentalized into numerous nanofluidic reservoirs, enabling highly quantitative detection while minimizing contamination risks. Using a single chip, we successfully detect both SARS-CoV-2 and Influenza H3 RNA with a detection limit of 10 fM, demonstrating the Nano-dChip's potential as a rapid, low-cost, and scalable diagnostic platform for timely outbreak control.

bioRxiv (Cold Spring Harbor Laboratory)
University of California, Riverside (US), Biological Mimetics (United States) (US)
Good health and well-being
Openalex Percentile: Top 14%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.