False-positive point-of-care urine beta human chorionic gonadotropin testing: Insights from two clinical cases

Case oneA young woman presented to the Early Pregnancy Assessment Unit (EPAU) with abdominal pain, amenorrhoea and variably positive home-pregnancy tests. On review, a point-of-care test (POCT) for urine beta-HCG (β-HCG) was negative but a blood test using the Abbott i-STAT β-HCG POCT device was positive. Initial transvaginal ultrasound did not demonstrate an intra- or extra-uterine pregnancy. Over the following 2 months, weekly plasma POCT iSTAT β-HCG checks remained positive. After a further ultrasound suggesting a possible ectopic pregnancy, the patient underwent a diagnostic laparoscopy which was unremarkable. Post-operatively, POCT iSTAT β-HCG levels remained elevated, and a blood sample was sent for laboratory analysis revealing an undetectable β-HCG of <1.20 IU/L (reference interval 0-4).Case twoA middle-aged woman presented to the emergency department with mons pubis pain and swelling and was admitted to the gynaecology ward for drainage of bilateral abscesses. On review, she had raised blood β-HCG levels, measured using the Abbott i-STAT POCT device. A subsequent blood sample sent for laboratory analysis showed β-HCG levels within the post-menopausal reference interval. <b>Discussion:</b> In both cases, POCT immunoassay interference was confirmed by consistent results produced when contemporaneous samples were analysed by different analytical platforms. Immunoassay interference, though rare, can lead to inaccurate results from POCT devices, potentially impacting patient diagnosis and management. Clinical teams should remain vigilant for this possibility; if test results do not align with clinical expectations, it is essential to promptly send a blood sample for laboratory analysis.

Authors

Institutions

Publication Details

Journal
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Published
2026-03-21
DOI
https://doi.org/10.1177/00045632261433346
Primary Topic
Ectopic Pregnancy Diagnosis and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

False-positive point-of-care urine beta human chorionic gonadotropin testing: Insights from two clinical cases

Mayur Patel, H. Fourie, Brian Shine, Ingrid Granne et al.
Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Ectopic Pregnancy Diagnosis and Management
article

False-positive point-of-care urine beta human chorionic gonadotropin testing: Insights from two clinical cases

Mayur Patel, H. Fourie, Brian Shine, Ingrid Granne, Darmiga Thayabaran, Gordana Fricker, Gayani Nilmini Dissanayake
article en

Abstract

Case oneA young woman presented to the Early Pregnancy Assessment Unit (EPAU) with abdominal pain, amenorrhoea and variably positive home-pregnancy tests. On review, a point-of-care test (POCT) for urine beta-HCG (β-HCG) was negative but a blood test using the Abbott i-STAT β-HCG POCT device was positive. Initial transvaginal ultrasound did not demonstrate an intra- or extra-uterine pregnancy. Over the following 2 months, weekly plasma POCT iSTAT β-HCG checks remained positive. After a further ultrasound suggesting a possible ectopic pregnancy, the patient underwent a diagnostic laparoscopy which was unremarkable. Post-operatively, POCT iSTAT β-HCG levels remained elevated, and a blood sample was sent for laboratory analysis revealing an undetectable β-HCG of <1.20 IU/L (reference interval 0-4).Case twoA middle-aged woman presented to the emergency department with mons pubis pain and swelling and was admitted to the gynaecology ward for drainage of bilateral abscesses. On review, she had raised blood β-HCG levels, measured using the Abbott i-STAT POCT device. A subsequent blood sample sent for laboratory analysis showed β-HCG levels within the post-menopausal reference interval. <b>Discussion:</b> In both cases, POCT immunoassay interference was confirmed by consistent results produced when contemporaneous samples were analysed by different analytical platforms. Immunoassay interference, though rare, can lead to inaccurate results from POCT devices, potentially impacting patient diagnosis and management. Clinical teams should remain vigilant for this possibility; if test results do not align with clinical expectations, it is essential to promptly send a blood sample for laboratory analysis.

Annals of Clinical Biochemistry International Journal of Laboratory Medicine
Nuffield Health (GB), Oxford University Hospitals NHS Trust (GB), Sobhraj Maternity Hospital (PK)
Good health and well-being
Openalex Percentile: Top 16%
Ectopic Pregnancy Diagnosis and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.