Explainable machine learning approach for unveiling the influence of conical strip design on heat exchanger performance under laminar flow

• Explainable ML techniques were used to optimize heat exchanger performance with conical strip inserts. • Decision Tree and SHAPley analyses were used to determine the impact of various design parameters. • High Re , low pitch ratio (PR), and high strip number enhance the Nu , while a high Re , PR, and twist angle increase the friction factor. • A low-level friction factor can be achieved by maintaining Re and PR values higher than 325 and 2.26, respectively. • Optimal ranges and influential features for enhancing thermo-hydraulic performance were identified, offering valuable insights for heat exchanger design. In this study, decision tree classification and SHAP explainable machine learning techniques were applied for the first time to analyze and optimize the thermal hydraulic performance of heat exchangers equipped with conical strip inserts operating under laminar flow. A dataset containing 400 rows of digitized experimental measurements from six published studies was constructed to determine the impact of various design parameters, such as geometry, arrangement, and number of conical strips (SN), on key performance indicators, including the Nusselt number ( Nu ), friction factor ( f ), and performance evaluation criterion (PEC). Results showed that a high Reynolds number ( Re ), a low pitch ratio (PR), and a high SN enhance the Nu , while a high Re , PR, and twist angle increase the f . When the strip-to-width ratio (SW) is less than 0.93, Re is between 550 and 1000, and PR is less than or equal to 1.75, the staggered arrangement of conical strips yields a geometry angle of 52.5° or less, allowing a high Nu to be achieved. Additionally, a low f can be achieved by maintaining Re and PR above 325 and 2.26, respectively. By analyzing existing literature data, this study identified optimal ranges and influential features to enhance thermo-hydraulic performance, offering valuable insights for future heat exchanger design. Ultimately, the research contributes to achieving the Sustainable Development Goals by improving energy conversion and efficiency.

Authors

Institutions

Publication Details

Journal
Thermal Science and Engineering Progress
Published
2026-03-21
DOI
https://doi.org/10.1016/j.tsep.2026.104653
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Explainable machine learning approach for unveiling the influence of conical strip design on heat exchanger performance under laminar flow

Zafer Yavuz Aksöz, Muhammad Aziz
Thermal Science and Engineering Progress
Heat Transfer and Optimization
article

Explainable machine learning approach for unveiling the influence of conical strip design on heat exchanger performance under laminar flow

Zafer Yavuz Aksöz, Muhammad Aziz
article en

Abstract

• Explainable ML techniques were used to optimize heat exchanger performance with conical strip inserts. • Decision Tree and SHAPley analyses were used to determine the impact of various design parameters. • High Re , low pitch ratio (PR), and high strip number enhance the Nu , while a high Re , PR, and twist angle increase the friction factor. • A low-level friction factor can be achieved by maintaining Re and PR values higher than 325 and 2.26, respectively. • Optimal ranges and influential features for enhancing thermo-hydraulic performance were identified, offering valuable insights for heat exchanger design. In this study, decision tree classification and SHAP explainable machine learning techniques were applied for the first time to analyze and optimize the thermal hydraulic performance of heat exchangers equipped with conical strip inserts operating under laminar flow. A dataset containing 400 rows of digitized experimental measurements from six published studies was constructed to determine the impact of various design parameters, such as geometry, arrangement, and number of conical strips (SN), on key performance indicators, including the Nusselt number ( Nu ), friction factor ( f ), and performance evaluation criterion (PEC). Results showed that a high Reynolds number ( Re ), a low pitch ratio (PR), and a high SN enhance the Nu , while a high Re , PR, and twist angle increase the f . When the strip-to-width ratio (SW) is less than 0.93, Re is between 550 and 1000, and PR is less than or equal to 1.75, the staggered arrangement of conical strips yields a geometry angle of 52.5° or less, allowing a high Nu to be achieved. Additionally, a low f can be achieved by maintaining Re and PR above 325 and 2.26, respectively. By analyzing existing literature data, this study identified optimal ranges and influential features to enhance thermo-hydraulic performance, offering valuable insights for future heat exchanger design. Ultimately, the research contributes to achieving the Sustainable Development Goals by improving energy conversion and efficiency.

Thermal Science and Engineering ProgressVol. 73
Istanbul Bilgi University (TR), The University of Tokyo (JP)
Openalex Percentile: Top 13%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.